This manual provides usage instructions, precautions, and troubleshooting guides for the SMC VBA series booster valve.
The document serves as a user guide for the SMC VBA series booster valves. It outlines critical safety warnings regarding pressure fluctuations and residual pressure handling to prevent accidents. The text details proper installation procedures, including piping requirements, air source quality standards, and environmental conditions necessary for correct operation.
Additionally, the manual provides specific technical specifications for various models (VBA1110, VBA2*00, etc.), covering setting pressure ranges and maximum durability pressures. It includes a comprehensive troubleshooting section that correlates operational phenomena with their causes and recommended countermeasures. This manual is written in Japanese.
| Setting Pressure Range (VBA1110/1111/1311) | 0.2~2.0MPa |
|---|---|
| Supply Pressure Range (VBA1110/1111/1311) | 0.1~1.0MPa |
| Supply Pressure Range (VBA2*00/4*00) | 0.1~1.0MPa |
| Maximum Durability Pressure (VBA1110/1111/1311) | 3.0MPa |
| Operating Temperature Range | 2 ~ 50 ℃ (unfrozen) |
An oil mist separator (AM series type) must be installed on the primary side.
Connect a 3-way valve to the OUT side of the booster valve to rapidly remove secondary residual pressure.
The primary side must be equipped with a cleaner to ensure compressed air quality.