This manual covers SMC solid state auto switches in the D-G59, D-G5BA, D-G5P, and D-K59 series. It includes safety instructions, model indication and ordering information, product parts, definitions, mounting and installation, maintenance, troubleshooting, specifications, and dimensions.

It also states design and selection precautions such as minimum cylinder separation, maximum wire length, and maximum detectable piston speed, along with warranty and compliance requirements.

What's inside

  • Safety Instructions
  • Model Indication and How to Order
  • Summary of Product parts
  • Definition and terminology
  • Mounting and Installation
  • Installation
  • Maintenance
  • Troubleshooting
  • Specifications
  • Dimensions

Specifications

Warranty period1 year in service or 1.5 years after the product is delivered
Minimum cylinder separation40 mm
Maximum wire length100 m or less
Maximum detectable piston speedAuto switch operating range [mm] x 1000 / Time load applied [ms]

Frequently asked questions

What is the warranty period for the product?

The warranty period is 1 year in service or 1.5 years after the product is delivered, whichever is first.

What minimum separation is required between multiple cylinders or actuators?

Maintain a minimum cylinder separation of 40 mm.

What is the maximum recommended wire length?

Use a wire length of 100 m or less.

How is maximum detectable piston speed calculated?

V[mm/s] equals auto switch operating range [mm] times 1000 divided by time load applied [ms].