About this manual

This motor manual (V1.3, 01.2017) from Schneider Electric describes the BMP 2 synchronous motor. It states that the product is a motor intended for industrial use and that installation, operation, service and maintenance must be performed only by qualified personnel.

The manual covers safety information, product introduction, technical data, dimensions and shaft data, installation including EMC and electrical connection, commissioning, diagnostics and troubleshooting, accessories and spare parts such as the IP67 kit and motor cables, and service, maintenance and disposal. It also lists applications for which the motor is not intended, including cranes, elevators, vertical axes, applications with high moment of inertia and continuous regeneration conditions.

What's inside

  • Safety Information
  • Introduction
  • Technical Data
  • Installation
  • Commissioning
  • Diagnostics and troubleshooting
  • Accessories and spare parts
  • Service, maintenance and disposal
  • Glossary

Frequently asked questions

What is the BMP 2 synchronous motor intended for?

The BMP 2 is a motor intended for industrial use according to the manual. It may only be used in compliance with applicable safety regulations, directives, specified requirements and technical data.

Who is authorized to work on the product?

Only appropriately trained persons who are familiar with and understand the manual and all other pertinent product documentation, and who have received safety training, are authorized to work on and with the product.

What applications is the motor not intended for?

The motor is not intended for use in cranes, elevators, vertical axes, applications with high moment of inertia, or continuous regeneration conditions.

What must be done before working on the drive system?

Before work on the drive system, disconnect all power, place a "Do Not Turn On" label on power switches, lock them open, and wait 15 minutes for the DC bus capacitors to discharge. Then measure the DC bus voltage between PA/+ and PC/- with a properly rated voltmeter and verify it is less than 42 Vdc.