Operating manual for the Pilz PSEN cs6.1p safety switch, covering function, installation, wiring, operation, and safety requirements.
The Pilz PSEN cs6.1p is a safety switch using transponder technology for presence detection. This operating manual explains its function and operation, describes installation, and provides guidelines for connecting the product.
The manual covers safety requirements, unit features, wiring, actuator teaching, normal operation, error display, dimensions, technical details, and order references.
| Actuator | PSEN cs6.1 |
|---|---|
| Safety level | PL e (Cat. 4)/SIL CL 3 with 2-channel safety outputs |
| Coding | Fully coded |
| Actuation directions | 4 actuation directions, each with 3 approach directions |
| Safety Device Diagnostics series capacity | Up to 16 sensors |
| Safety inputs | 2 |
| Safety outputs | 2 |
It may only be used with the corresponding actuator PSEN cs6.1.
Up to 16 sensors connected in series can be connected as a subscriber to a fieldbus module.
It meets EN 60947-5-3 with actuator PSEN cs6.1, EN 62061 SIL CL 3, EN ISO 13849-1 PL e Cat. 4, and EN ISO 14119 coding level High, Type 4.
If a fieldbus module of the SDD is used, diagnostic input Y1 is automatically activated and data is read; otherwise it is not used.