User manual for the Pilz PSEN cs5.1 M12/8 coded transponder safety switch, covering intended use, wiring, mounting, operation, and technical data.
Pilz PSEN cs5.1 M12/8 is a coded transponder safety switch with two safety inputs and two safety outputs. It is intended for use with the corresponding PSEN cs5.1 M12 actuator and meets EN 60947-5-3, EN 62061 SIL CL 3, EN ISO 13849-1 PL e Cat. 4, and EN ISO 14119 requirements when its safety outputs are used in two-channel mode.
The manual describes device features, function states, block diagram, switching distances for rectangular and triangular marks, wiring, actuator programming, mounting, commissioning, error indications, dimensions, technical data, ordering data, accessories, and CE declaration. This manual is written in Italian.
| Safety inputs | 2 |
|---|---|
| Safety outputs | 2 |
| Signaling output | 1 |
| Guaranteed switching distance (rectangular mark) | 8 mm |
| Typical switching distance (rectangular mark) | 11 mm |
| Typical release distance (rectangular mark) | 14 mm |
| Guaranteed release distance (rectangular mark) | 20 mm |
| Guaranteed switching distance (triangular mark) | 4 mm |
| Typical switching distance (triangular mark) | 5 mm |
| Typical release distance (triangular mark) | 8 mm |
| Guaranteed release distance (triangular mark) | 12 mm |
| Safety level | PL e (Cat. 4)/SIL CL 3 with two-channel safety outputs |
PL e (Cat. 4)/SIL CL 3 when the safety outputs are used in two-channel mode.
A flashing yellow Input LED and a flashing red Device LED.
8 mm.