Pilz PSEN cs6.21n Safety Switch User Manual

Pilz PSEN cs6.21n safety switch user manual: transponder-based, unique coding, 2 safety outputs, PL e/SIL CL 3 with 2-channel evaluation.


Pilz PSEN cs6.21n Safety Switch User Manual - cover page
Brand
Pilz
Category
switch
Document type
User Manual
Language
German
Pages
31
File format
PDF
File size
1.4 MB
Published
13 November, 2026
Updated
13 November, 2026
MD5 checksum
25E17B7ACD88233347D20979CB734613

About this manual

Pilz PSEN cs6.21n is a transponder-based safety switch used with the actuator PSEN cs6.11 M12. It has two safety outputs, one diagnostic output, magnetic latching with a 30 N holding force, and unique Pilz coding.

The manual covers safety, mounting, wiring, operation, technical data, and order information. Guaranteed safe switching distance is 8 mm and guaranteed safe switch-off distance is 20 mm when the actuator is aligned to the rectangle marking. This manual is written in German.

What's inside

  • Introduction
  • Safety
  • Device features
  • Function description
  • Switching distances
  • Wiring
  • Mounting
  • Operation
  • Technical data
  • Order data

Specifications

ApprovalsCE, EAC, ECOLAB, FCC, IC, TÜV, UL/cUL
FunctionSensor transponder
Coding levelHigh
Type4
ClassificationPDDB
Pilz coding typeUnique coded
Transponder frequency band122 kHz - 128 kHz
Maximum transmit power15 mW
Holding force30 N
ActuatorPSEN cs6.11 M12
Supply voltage24 V DC
Supply voltage tolerance-20 %/+20 %
External power supply power1 W
Maximum switching frequency3 Hz
No-load current25 mA
Maximum inrush current pulse0.5 A
Switching current per output100 mA
Switching power per output2.4 W
Residual current at outputs400 µA
Voltage drop at OSSDs1 V
Conditional rated short-circuit current100 A
Smallest operating current2 mA
Utilization categoryDC-12
Maximum test pulse duration150 µs
Switch-on delay1 s
Actuator response timeTyp. 30 ms, max. 50 ms
Maximum cable capacitance at safety outputs40 nF
Safe switching distance (Sao)8 mm
Safe switch-off distance (Sar)20 mm
Typical switching distance (So)11 mm
Typical switch-off distance (Sr)14 mm
Pacemaker safety distanceAt least 100 mm
FuseFast-blow, 2 A to 4 A
Power supply typeSELV/PELV
Safety levelPL e (Cat. 4)/SIL CL 3 with 2-channel processing

Frequently asked questions

Which actuator must be used with the PSEN cs6.21n?

It may only be used with the associated actuator PSEN cs6.11 M12.

What is the guaranteed safe switch-off distance?

The guaranteed safe switch-off distance (Sar) is 20 mm when the actuator is aligned to the rectangle marking.

What supply voltage does the switch require?

The supply voltage is 24 V DC with a tolerance of -20 %/+20 %.

What distance must people with pacemakers keep from the switch?

They must keep a distance of at least 100 mm from the safety switch and the actuator.

Download PDF (1.4 MB)

More Pilz Manuals


View all Pilz manuals →