Pilz PSEN cs6.21n safety switch user manual: transponder-based, unique coding, 2 safety outputs, PL e/SIL CL 3 with 2-channel evaluation.
Pilz PSEN cs6.21n is a transponder-based safety switch used with the actuator PSEN cs6.11 M12. It has two safety outputs, one diagnostic output, magnetic latching with a 30 N holding force, and unique Pilz coding.
The manual covers safety, mounting, wiring, operation, technical data, and order information. Guaranteed safe switching distance is 8 mm and guaranteed safe switch-off distance is 20 mm when the actuator is aligned to the rectangle marking. This manual is written in German.
| Approvals | CE, EAC, ECOLAB, FCC, IC, TÜV, UL/cUL |
|---|---|
| Function | Sensor transponder |
| Coding level | High |
| Type | 4 |
| Classification | PDDB |
| Pilz coding type | Unique coded |
| Transponder frequency band | 122 kHz - 128 kHz |
| Maximum transmit power | 15 mW |
| Holding force | 30 N |
| Actuator | PSEN cs6.11 M12 |
| Supply voltage | 24 V DC |
| Supply voltage tolerance | -20 %/+20 % |
| External power supply power | 1 W |
| Maximum switching frequency | 3 Hz |
| No-load current | 25 mA |
| Maximum inrush current pulse | 0.5 A |
| Switching current per output | 100 mA |
| Switching power per output | 2.4 W |
| Residual current at outputs | 400 µA |
| Voltage drop at OSSDs | 1 V |
| Conditional rated short-circuit current | 100 A |
| Smallest operating current | 2 mA |
| Utilization category | DC-12 |
| Maximum test pulse duration | 150 µs |
| Switch-on delay | 1 s |
| Actuator response time | Typ. 30 ms, max. 50 ms |
| Maximum cable capacitance at safety outputs | 40 nF |
| Safe switching distance (Sao) | 8 mm |
| Safe switch-off distance (Sar) | 20 mm |
| Typical switching distance (So) | 11 mm |
| Typical switch-off distance (Sr) | 14 mm |
| Pacemaker safety distance | At least 100 mm |
| Fuse | Fast-blow, 2 A to 4 A |
| Power supply type | SELV/PELV |
| Safety level | PL e (Cat. 4)/SIL CL 3 with 2-channel processing |
It may only be used with the associated actuator PSEN cs6.11 M12.
The guaranteed safe switch-off distance (Sar) is 20 mm when the actuator is aligned to the rectangle marking.
The supply voltage is 24 V DC with a tolerance of -20 %/+20 %.
They must keep a distance of at least 100 mm from the safety switch and the actuator.