Pilz PSEN cs3.1p/M12 Safety Switch Operating Manual

The PSEN cs3.1p/M12 is a safety light curtain that protects personnel from hazardous areas. Its features include:


Pilz PSEN cs3.1p/M12 Safety Switch Operating Manual - cover page
Brand
Pilz
Category
switch
Document type
User Manual
Language
English
Pages
29
File format
PDF
File size
1.1 MB
Published
07 November, 2023
Updated
07 November, 2023
MD5 checksum
BA9CF8D0839CF8D4DA610B39488E28D3

About this manual

The Pilz PSEN cs3.1p/M12 Operating Manual explains the function and operation of the PSEN cs3.1p/M12 safety switch and describes its installation and connection. It is valid for this product until new documentation is published.

The switch uses transponder technology for presence detection and has Pilz coding type Coded, dual-channel operation, two safety inputs, two safety outputs, one signal output and an LED display for actuator state, input state and supply voltage/fault. It may only be used with the corresponding actuator PSEN cs3.1.

What's inside

  • Introduction
  • Safety
  • Unit features
  • Function description
  • Operating distances
  • Wiring
  • Installation
  • Adjustment
  • Operation
  • Technical details

Specifications

Safety function2 safety outputs, each supplying a high signal when the actuator is in the response range and the safety inputs are high
Safety inputs2 safety inputs for series connection of multiple safety switches
Signal output1 signal output
Coding typePilz coding type: Coded
Safety switch standardEN 60947-5-3 with actuator PSEN cs3.1: PDDB
Functional safetyEN 62061: SIL CL 3
Performance levelEN ISO 13849-1: PL e Cat. 4
Interlocking deviceEN ISO 14119: Coding level Low, Type 4
Assured operating distance Sao8 mm
Typical operating distance So11 mm
Typical release distance Sr14 mm
Assured release distance Sar20 mm
Connection type PSEN cs3.1p8-pin M8 male connector
Connection type PSEN cs3.1 M12/8-0.15m8-pin M12 male connector, 0.15 m cable
Connection type PSEN cs3.1 M12/8-1.5m8-pin M12 male connector, 1.5 m cable
Minimum permitted supply voltage at sensor19.2 V

Frequently asked questions

What is the safety function of the PSEN cs3.1p/M12?

The safety switch has two safety outputs, each of which supplies a high signal when the actuator is in the response range and there is a high signal at the safety inputs.

Which actuator may be used with the safety switch?

The safety switch may only be used with the corresponding actuator PSEN cs3.1.

What connector does the PSEN cs3.1p version use?

The PSEN cs3.1p version uses an 8-pin M8 male connector.

How must the supply voltage to the safety switch be protected?

The supply voltage to the safety switch must be protected with a 2 A to 4 A quick-acting fuse.