The Phocos ECO-N-MPPT 85/15 solar charge controller user manual provides installation, connection, and safe operating instructions for 12/24 V DC systems.
This user manual covers the Phocos ECO-N-MPPT 85/15 solar charge controller. It contains safety information, installation steps, connection instructions, and operating guidance for the charge controller.
The controller uses MPPT technology with a maximum system efficiency of 98% and is designed for 12/24 V DC systems. It supports 60-cell PV modules, has an IP68 housing and IP21 terminals, and is compatible with lead-acid, GEL, and AGM batteries. This manual is written in German.
| System voltage | 12/24 V auto recognition |
|---|---|
| Max. charge current | 15 A |
| Max. load current | 15 A |
| Max. usable PV power | 225 W @ 12 V, 450 W @ 24 V |
| Max. PV array power | 250 Wp @ 12 V, 500 Wp @ 24 V |
| Float charge voltage | 13.8/27.6 V (25 °C) |
| Main charge voltage | 14.4/28.8 V (25 °C), 0.5 h daily |
| Deep discharge cut-off voltage | 11.0/22.0 V |
| Overvoltage protection | 15.5/31.0 V |
| Housing protection rating | IP68 housing, IP21 terminals |
It supports 12/24 V systems with automatic voltage recognition.
The maximum charge current is 15 A.
It is suitable for lead-acid batteries with liquid electrolyte and lead-acid batteries with solid electrolyte such as GEL or AGM.
It switches off at a low battery voltage of 11.0/22.0 V.