Phocos ECO-N-MPPT 85/15 Solar charge controller User Manual

The Phocos ECO-N-MPPT 85/15 solar charge controller user manual provides installation, connection, and safe operating instructions for 12/24 V DC systems.


Phocos ECO-N-MPPT 85/15 Solar charge controller User Manual - cover page
Brand
Phocos
Category
Charge Controller
Document type
User Manual
Language
German
Pages
62
File format
PDF
File size
839 KB
Published
15 November, 2026
Updated
15 November, 2026
MD5 checksum
9E176D4B233AEEE9B4CD1285DDDC2AC4

About this manual

This user manual covers the Phocos ECO-N-MPPT 85/15 solar charge controller. It contains safety information, installation steps, connection instructions, and operating guidance for the charge controller.

The controller uses MPPT technology with a maximum system efficiency of 98% and is designed for 12/24 V DC systems. It supports 60-cell PV modules, has an IP68 housing and IP21 terminals, and is compatible with lead-acid, GEL, and AGM batteries. This manual is written in German.

What's inside

  • Important general safety instructions
  • Connection and grounding
  • Commissioning of the charge controller
  • Display and warning function
  • Safety functions
  • Deep discharge protection
  • Error description
  • Technical data

Specifications

System voltage12/24 V auto recognition
Max. charge current15 A
Max. load current15 A
Max. usable PV power225 W @ 12 V, 450 W @ 24 V
Max. PV array power250 Wp @ 12 V, 500 Wp @ 24 V
Float charge voltage13.8/27.6 V (25 °C)
Main charge voltage14.4/28.8 V (25 °C), 0.5 h daily
Deep discharge cut-off voltage11.0/22.0 V
Overvoltage protection15.5/31.0 V
Housing protection ratingIP68 housing, IP21 terminals

Frequently asked questions

What system voltages does the Phocos ECO-N-MPPT 85/15 support?

It supports 12/24 V systems with automatic voltage recognition.

What is the maximum charge current of the ECO-N-MPPT 85/15?

The maximum charge current is 15 A.

Which battery types can be used with the ECO-N-MPPT 85/15?

It is suitable for lead-acid batteries with liquid electrolyte and lead-acid batteries with solid electrolyte such as GEL or AGM.

At what voltage does deep discharge protection switch off the load output?

It switches off at a low battery voltage of 11.0/22.0 V.

Download PDF (839 KB)

More Phocos Manuals