Phocos CIS Solar Controller Datasheet

This document describes the features and characteristics of the CIS high protection level multifunctional solar controller, including dust and waterproof epoxy resin filled PCB board, durable aluminum housing, and easy-to-use infrared remote control.


Brand
Phocos
Document type
Datasheet
Language
Chinese
Pages
1
File format
PDF
File size
3.1 MB
Updated
28 September, 2023
MD5 checksum
2CD1807DB21CF0EEBC8B41F07E5C9644

About this manual

The CIS series solar controller from Phocos is designed for small off‑grid solar systems and meets industrial‑grade standards. It offers multiple load control modes, two‑stage battery charging, and optional external temperature compensation.

Key specifications include a rated voltage of 12/24 V, maximum charge/discharge current of 5 A, IP68 protection, operation from –40 °C to +60 °C, and support for solar panel voltages up to 55 V. The unit is compact (82 × 58 × 20 mm) and lightweight (≈150 g). This manual is written in Chinese.

What's inside

  • Technical Specifications
  • Charging Parameters
  • Voltage Settings
  • Load Control Modes
  • Environmental Ratings
  • Dimensions and Weight
  • Contact Information

Specifications

Maximum Charge/Discharge Current5 A
Float Voltage13.8 V (25 °C)
Low‑Voltage Protection11.00‑12.02 V / 22.00‑24.04 V
Temperature Compensation Coefficient-4.2 mV/A·K per cell
Maximum Solar Panel Voltage55 V
IP Protection RatingIP68
Operating Temperature Range-40 °C to +60 °C
Maximum Altitude4000 m
Dimensions82 × 58 × 20 mm
Weight≈150 g
Cable Length10 cm

Frequently asked questions

What is the IP protection rating of the CIS solar controller?

The controller is rated IP68, providing dust‑tight and water‑resistant protection.

What are the charging voltage settings for the CIS controller?

Bulk voltage is 14.47 V (12 V system) or 28.8 V (24 V system), absorption voltage is 14.8 V / 29.6 V, and float voltage is 13.8 V.

What is the maximum charge/discharge current of the controller?

The maximum charge and discharge current is 5 A.

What temperature range can the controller operate in?

It operates from –40 °C up to +60 °C.