User manual for Phocos hybrid charger pure sine wave inverters with MPPT solar charging, covering installation, operation, troubleshooting, and technical specs.
This manual covers the installation, operation, and maintenance of Phocos Any-Grid™ hybrid charger pure sine wave inverters. It includes safety warnings, connection instructions for battery, solar, and AC inputs/outputs, and operation modes including grid-tied and off-grid. The inverters support MPPT solar charging and can be configured for battery charging or grid feeding with PIN code protection. Features include Bluetooth connectivity via PhocosLink app, remote display units, and multi-unit parallel or phase connections.
Technical specifications are provided for grid-tied, off-grid, and battery charging modes, including voltage and power ratings for different models. Safety precautions cover grounding, surge protection, and battery handling. The manual also includes fault codes, alarm codes, and troubleshooting steps for common issues. This manual is written in Chinese.
| Input Voltage | 230 Vac or 120 Vac |
|---|---|
| Output Voltage | 230 Vac or 120 Vac |
| Battery Type | Lead-acid (gel, AGM, liquid) and LiFePO4 |
| MPPT Solar Charging | Yes |
| Surge Power | Double the rated power |
| Grid-Tied Feeding | Yes, with PIN code lock |
| Bluetooth Connectivity | PhocosLink BLE app |
| Remote Display Unit | Yes, up to 20m (6 ft) away |
Yes, it can be used in grid-tied mode, but it requires a PIN code to prevent accidental feeding into the grid.
It is compatible with lead-acid batteries (gel, AGM, liquid) and LiFePO4 batteries.
You can monitor the inverter using the PhocosLink BLE smartphone Bluetooth app.