Perkin Elmer LS-50B Luminescence Spectrometer User’s Guide

User guide for the LS-50B Luminescence Spectrometer covering safety, installation, operation, and maintenance.


Perkin Elmer LS-50B Luminescence Spectrometer User’s Guide - cover page
Brand
PerkinElmer
Document type
User Manual
Language
English
Pages
208
File format
PDF
File size
5.2 MB
Published
06 November, 2026
Updated
06 November, 2026
Model
LS-50B
MD5 checksum
87A362926FA989190ACE0EDE3435EB61

About this manual

This manual provides detailed instructions for safely operating and maintaining the LS-50B Luminescence Spectrometer. It covers installation procedures, accessory setup, safety precautions, and technical commands for system control. The guide also includes specifications, maintenance tips, and troubleshooting information for optimal instrument performance.

The LS-50B is a computer-controlled ratioing luminescence spectrometer capable of measuring fluorescence, phosphorescence, chemiluminescence, and bioluminescence. It features a xenon discharge lamp, gated photomultipliers, and Monk-Gillieson monochromators for precise wavelength control and spectral analysis.

What's inside

  • Warnings and Safety Information
  • Introduction
  • Specifications of the LS-50B
  • Unpacking and Installation
  • Accessories: Installation and Use
  • RS232 Commands
  • System Description and Maintenance

Specifications

PrincipleComputer controlled ratioing luminescence spectrometer
SourceXenon discharge lamp, equivalent to 20 kW for 8 µs duration
Sample detectorGated photomultiplier with modified S5 response for operation up to around 650 nm
Wavelength accuracy+ 1.0 nm
Wavelength reproducibility+ 0.5 nm
Excitation range200-800 nm with zero order selectable
Emission range200-650 nm with standard photomultiplier, 200-900 nm with optional R928 photomultiplier

Frequently asked questions

What are the wavelength accuracy and reproducibility specifications?

The wavelength accuracy is ±1.0 nm and the reproducibility is ±0.5 nm.

What environmental conditions are required for the safe operation of the LS-50B?

The instrument operates correctly indoors at ambient temperatures between 15 °C and 35 °C with a relative humidity of 75% maximum, non-condensing.

What is the wavelength accuracy and reproducibility of the LS-50B?

The wavelength accuracy is + 1.0 nm and the wavelength reproducibility is + 0.5 nm.

What is the minimum total period for phosphorescence measurements?

The minimum total period for phosphorescence mode is 13.0 ms (50 Hz).

Download PDF (5.2 MB)