Reference and installation manual for Paradox MG5000/MG5050/SP4000/SP5500/SP6000/SP7000 alarm systems, covering installation and programming.
Paradox publishes this Reference & Installation Manual for the MG5000 V4.7, MG5050 V4.7, MG5050 EN V4.96, SP4000 V5.1, SP5500 V4.9, SP6000 V4.9 and SP7000 V4.9 alarm systems. The table of contents covers introduction, features, system overview, specifications, installation, programming methods, access codes, StayD mode, zone programming, wireless features, reporting and dialer settings, programmable outputs, system settings and user operation.
The first pages list installation considerations for the AUX output and battery, explain warranty and alarm-system limitations, and give TBR-21 and UL/ULC warnings for installers. They also state battery voltage thresholds, allowed entry and exit delays, bell cut-off time and output ratings.
| Maximum AUX ripple voltage | 500 millivolts peak-to-peak |
|---|---|
| Low battery voltage threshold | Below 10.7 volts |
| Deep discharge protection | 7.7 ± 0.3 volts |
| Fault signal threshold | Below 11.3 volts |
| Output voltage rating | 11.3 Vdc to 13.5 Vdc |
| Backup battery | 12 Vdc 4 Ah rechargeable acid/lead or gel cell |
| UL985 auxiliary power output | Not more than 200 mA |
| Maximum allowed entry delay | 45 seconds |
| Maximum allowed exit delay | 60 seconds |
| Minimum bell cut-off time | 4 minutes |
The maximum peak-to-peak ripple voltage on AUX is 500 millivolts.
A low voltage on the battery is generated when the battery is below 10.7 volts.
The maximum allowed entry delay is 45 seconds.
Complete warranty information is in the Limited Warranty Statement on www.paradox.com.