32-Zone Wireless Transceiver Security Systems MG5000 • MG5050 Version 4.7, 4 to 32-Zone Expandable Security Systems SP5500 • SP6000 • SP7000 Version 4.7 SP4000 • SP65 Version 4.8 programming guide

This file is about 32-Zone Wireless Transceiver Security Systems MG5000 • MG5050 Version 4.7, 4 to 32-Zone Expandable Security Systems SP5500 • SP6000 • SP7000 Version 4.7 SP4000 • SP65 Version 4.8 programming guide


32-Zone Wireless Transceiver Security Systems MG5000 • MG5050 Version 4.7, 4 to 32-Zone Expandable Security Systems SP5500 • SP6000 • SP7000 Version 4.7 SP4000 • SP65 Version 4.8 programming guide - cover page
Brand
PARA Dox
Category
Other Electronics
Document type
Programming Manual
Language
English
Pages
58
File format
PDF
File size
890 KB
Published
01 November, 2023
Updated
01 November, 2023
MD5 checksum
028ED12E8A9997E5D6B57D8E55A9E797

About this manual

This programming guide is for Paradox Magellan and Spectra SP security systems, including MG5000, MG5050, SP5500, SP6000, SP7000, SP4000, and SP65. It is used with the Magellan and Spectra SP Reference & Installation Manual to record programmed settings.

It covers installer and maintenance codes, panel reset, programming mode, data entry and display, version numbers, decimal and hexadecimal programming, and UL/ULC installation warnings.

What's inside

  • Warranty
  • Limitations of Alarm Systems
  • UL And ULC Warnings
  • Things You Need to Know
  • Conventions
  • Panel Reset
  • Entering Programming Mode
  • Data Entry and Display
  • Viewing Version Numbers
  • Decimal and Hexadecimal Programming

Specifications

Default installer code0000 or 000000
Default system master code1234 or 123456
Maximum entry delay (UL)45 seconds
Maximum exit delay (UL)60 seconds
Minimum bell cut-off time (UL)4 minutes
Auxiliary power output (UL)should not exceed 200mA
Output voltage range11.3 Vdc to 12.7 Vdc
Backup battery12 Vdc 4 Ah rechargeable acid/lead or gel cell
EOL resistor part number2011002000
UL transformerUniversal UB1640W 16.5VAC min 40VA
SirenWheelock 46T-12

Frequently asked questions

What is the default installer code?

The default installer code is 0000 or 000000.

What is the default system master code?

The default system master code is 1234 or 123456.

How do I perform a panel reset on an SP4000 or SP65?

Remove the battery and AC power, remove connected wires and devices from the PG1 and zone 1 terminals, short PG1 and zone 1 with a wire, reconnect AC and battery power, then remove the jumper wire.

What are the UL entry and exit delay limits?

The maximum allowed entry delay is 45 seconds and the maximum allowed exit delay is 60 seconds.