This file is about 32-Zone Wireless Transceiver Security Systems MG5000 • MG5050 Version 4.7, 4 to 32-Zone Expandable Security Systems SP5500 • SP6000 • SP7000 Version 4.7 SP4000 • SP65 Version 4.8 programming guide
This programming guide is for Paradox Magellan and Spectra SP security systems, including MG5000, MG5050, SP5500, SP6000, SP7000, SP4000, and SP65. It is used with the Magellan and Spectra SP Reference & Installation Manual to record programmed settings.
It covers installer and maintenance codes, panel reset, programming mode, data entry and display, version numbers, decimal and hexadecimal programming, and UL/ULC installation warnings.
| Default installer code | 0000 or 000000 |
|---|---|
| Default system master code | 1234 or 123456 |
| Maximum entry delay (UL) | 45 seconds |
| Maximum exit delay (UL) | 60 seconds |
| Minimum bell cut-off time (UL) | 4 minutes |
| Auxiliary power output (UL) | should not exceed 200mA |
| Output voltage range | 11.3 Vdc to 12.7 Vdc |
| Backup battery | 12 Vdc 4 Ah rechargeable acid/lead or gel cell |
| EOL resistor part number | 2011002000 |
| UL transformer | Universal UB1640W 16.5VAC min 40VA |
| Siren | Wheelock 46T-12 |
The default installer code is 0000 or 000000.
The default system master code is 1234 or 123456.
Remove the battery and AC power, remove connected wires and devices from the PG1 and zone 1 terminals, short PG1 and zone 1 with a wire, reconnect AC and battery power, then remove the jumper wire.
The maximum allowed entry delay is 45 seconds and the maximum allowed exit delay is 60 seconds.