Micsig DP750 High Voltage Differential Probe User Manual

User manual for the Micsig DP750 high voltage differential probe covering specifications, operation, precautions, warranty, and safety.


Micsig DP750 High Voltage Differential Probe User Manual - cover page
Brand
Micsig
Category
Differential Probes
Document type
User Manual
Language
English
Pages
2
File format
PDF
File size
601 KB
Published
16 November, 2026
Updated
16 November, 2026
Model
DP750
MD5 checksum
235C13F4218A4331DE64589A82CB8AED

About this manual

The Micsig DP750 is a high voltage differential probe with a built-in shielded test line and compact interface box. It provides a maximum 100 MHz bandwidth, a maximum input voltage of 750 V, switchable 50X/500X attenuation, one-press zero calibration, and an overvoltage alarm.

The manual covers the probe's specifications, panel description, operation steps, precautions, warranty, and safety. Applications listed in the text include research and development, commissioning, or maintenance of switching power supplies, frequency converters, electronic ballasts, frequency conversion home appliances, and other electrical power devices.

What's inside

  • Overview
  • Specifications
  • Panel Description
  • Operation Steps
  • Precautions
  • Warranty
  • Safety

Specifications

Bandwidth100 MHz (DP750-100); 50 MHz (DP750-50)
Rise Time≤ 3.5 ns (DP750-100); ≤ 7 ns (DP750-50)
Attenuation Ratio50X; 500X
Gain Accuracy±2%
Max Differential Test Voltage (DC+AC PK)50X: 75 V; 500X: 750 V
Max Common Mode Input VoltageCAT II 600 V
Input Referred Noise≤ 12 mVrms (50X); ≤ 120 mVrms (500X)
Common Mode Rejection Ratio (CMRR)> 80 dB (DC); > 80 dB (100 kHz); > 60 dB (1 MHz)
Differential Input Impedance8 MΩ || 1.25 pF
Output Voltage≤ 1.5 V
Power Rate1 W
Power SupplyMicsig UPI Interface; USB (Adaptor)
DimensionsPower Supply Box: 80*37*22 mm; Signal In/Output Box: 49*25*12.5 mm
Working Humidity10%-85%

Frequently asked questions

How do I perform zero calibration on the DP750?

Short-circuit the two input terminals, power on, press and hold the Zero button for 3 seconds; the two indicators flash and calibration succeeds after 3 seconds.

What oscilloscope bandwidth is required?

The oscilloscope bandwidth must be no less than 100 MHz.

How do I power the DP750 with an oscilloscope that has no Micsig UPI?

Connect the probe to power adapter PA05, connect it to the oscilloscope input channel, then connect the Type-C cable to a 5V DC supply.

What is the warranty period for the DP750 main body?

The main body is guaranteed for 1 year under normal use.