Micsig DP750 High Voltage Differential Probe User Manual
The Micsig DP750 is a high voltage differential probe with a built-in shielded test line and compact interface box. It provides a maximum 100 MHz bandwidth, a maximum input voltage of 750 V, switchable 50X/500X attenuation, one-press zero calibration, and an overvoltage alarm.
The manual covers the probe's specifications, panel description, operation steps, precautions, warranty, and safety. Applications listed in the text include research and development, commissioning, or maintenance of switching power supplies, frequency converters, electronic ballasts, frequency conversion home appliances, and other electrical power devices.
Micsig DP750 specifications
| Bandwidth | 100 MHz (DP750-100); 50 MHz (DP750-50) |
|---|---|
| Rise Time | ≤ 3.5 ns (DP750-100); ≤ 7 ns (DP750-50) |
| Attenuation Ratio | 50X; 500X |
| Gain Accuracy | ±2% |
| Max Differential Test Voltage (DC+AC PK) | 50X: 75 V; 500X: 750 V |
| Max Common Mode Input Voltage | CAT II 600 V |
| Input Referred Noise | ≤ 12 mVrms (50X); ≤ 120 mVrms (500X) |
| Common Mode Rejection Ratio (CMRR) | > 80 dB (DC); > 80 dB (100 kHz); > 60 dB (1 MHz) |
| Differential Input Impedance | 8 MΩ || 1.25 pF |
| Output Voltage | ≤ 1.5 V |
| Power Rate | 1 W |
| Power Supply | Micsig UPI Interface; USB (Adaptor) |
| Dimensions | Power Supply Box: 80*37*22 mm; Signal In/Output Box: 49*25*12.5 mm |
| Working Humidity | 10%-85% |
Source: Micsig DP750 High Voltage Differential Probe User Manual
All Micsig DP750 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
How do I perform zero calibration on the DP750?
Short-circuit the two input terminals, power on, press and hold the Zero button for 3 seconds; the two indicators flash and calibration succeeds after 3 seconds.
From: Micsig DP750 High Voltage Differential Probe User Manual
What oscilloscope bandwidth is required?
The oscilloscope bandwidth must be no less than 100 MHz.
From: Micsig DP750 High Voltage Differential Probe User Manual
How do I calibrate the zero point of the probe?
Short the two input terminals, power on, and long press the 'Zero' button for 3 seconds until the two indicator lights flash simultaneously.
What are the oscilloscope requirements for connecting the differential probe?
The oscilloscope bandwidth must be no lower than 100MHz, and the channel input impedance must be no lower than 1MΩ.