Juniper Systems HCGG Slope and Motion Sensor Replacement Guide

Instructions for removing, installing, and reconfiguring the Slope and Motion Sensor (SMS) box on the HCGG HarvestMaster system.


Juniper Systems HCGG Slope and Motion Sensor Replacement Guide - cover page
Brand
Juniper Systems
Category
Other
Document type
Service Manual
Language
English
Pages
11
File format
PDF
File size
933 KB
Published
19 November, 2026
Updated
19 November, 2026
MD5 checksum
519DB4A482A04106CAF85E5FE0F4B9A9

About this manual

This guide provides step-by-step instructions for replacing the existing Slope and Motion Sensor (SMS) box and mounting brace on the HCGG HarvestMaster system. It covers the removal of the old unit, installation of the new 0.675 lb SMS box, and the necessary mechanical adjustments to the mounting beam and brace.

What's inside

  • Parts list
  • Required tools
  • Removing the old SMS Box
  • Installing the new SMS Box
  • Re-routing cables
  • Preparing the HCGG for use
  • Changing the SMS weight

Specifications

SMS Box Weight0.675 lb
Part Number14918-01
Release DateOctober 2006

Frequently asked questions

What tools are required for the SMS replacement?

You need a 5/32" allen wrench, a 3/16" allen wrench, and a 7/16" socket and ratchet.

How do I change the reference weight in the field computer?

Navigate to Setup / Weight/Bucket / S & M Sensor and enter 0.675 U.S. units in the Ref Wt field.

Download PDF (933 KB)