Datasheet for ignition transformers types T8, T16/D, T18 and T20 with technical data, construction, dimensions and installation notes.
This document describes ignition transformers types T8..., T16/D, T18... and T20..., which share overall dimensions but have different electrical features and fixing systems. It covers their applications, features, technical data, construction, overall dimensions, connections and installation precautions.
The series includes column-type transformers with two primary and two secondary windings, except for the shell-type T16/D, and is isolated with vacuum cast polyester resin.
| Supply voltage | 220 V, 50 Hz (other values available on request) |
|---|---|
| Operating temperature range | -10°C to +60°C |
| Isolation | Polyester resin |
| Recommended electrode distance | 3 to 5 mm |
| Supply cable standard length | 700 mm |
| Number of poles | 2 for all types |
| Output peak voltage | 2 x 6.5 / 2 x 5 / 2 x 4.5 / 2 x 5 kV |
| Output effective current | 35 / 20 / 16 / 23 mA |
| Input effective current | 2.1 / 1,1 / 0.77 / 1.3 A |
| Duty cycle | 33% in 3 minutes / 33% in 3 minutes / 100% / 66% in 3 minutes |
| Power consumption | 460 / 240 / 170 / 285 VA |
| Weight | 3.5 / 30 / 3.7 / 3.2 kg |
220 V at 50 Hz; different voltage and frequency values are available on request.
3 to 5 mm.
Yes, the device can be mounted in any position.
Polyester resin.