HB HB100 10.525GHz Microwave Motion Sensor Module User Manual

HB100 X-band bi-static Doppler transceiver module: specifications, antenna patterns, installation notes and example application circuits.


HB HB100 10.525GHz Microwave Motion Sensor Module User Manual - cover page
Brand
HB
Category
sensor
Document type
User Manual
Language
Chinese
Pages
13
File format
PDF
File size
1 MB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
97E7A8BE9C947FE23C1B5E0E7C7B9B89

About this manual

The HB100 is an X-band bi-static Doppler transceiver module with a built-in dielectric resonator oscillator (DRO) and a pair of microstrip patch antennas. The document presents it for OEM motion-detection equipment, including microwave/PIR intrusion detectors, automatic door opening, lighting control and vehicle speed measurement. The English pages cover features, block diagram and connection, antenna beam patterns, an outline diagram and a specification table measured at +5 VDC, CW operation, 12 kΩ load and +25 °C.

The Chinese pages add installation notes (soldering the +5V, GND and IF pads, removing the wire that protects against static damage, antenna orientation and the three types of IF output signal), the Doppler equation Fd = 2v(Ft/c)cos q, and three example circuits: an automatic door / ATM recording control with 4–15 m adjustable range, a train signal switch circuit with 1–9 m range, and a PIR/microwave combined detector built around a PIC16C622A microcontroller. This manual is written in Chinese.

What's inside

  • Features
  • Description
  • Block diagram and connection
  • Antenna Beam Pattern
  • Technical Specifications
  • Outline diagram
  • Installation and connection
  • Output signal types
  • Doppler equation
  • Application example: automatic door and ATM control

Specifications

Frequency Setting10.520 GHz min, 10.525 GHz typ., 10.530 GHz max
Radiated Power (EIRP)12 dBm min, 15 dBm typ., 20 dBm max
Supply Voltage4.75 VDC min, 5.00 VDC typ., 5.25 VDC max
Current Consumption30 mA typ., 40 mA max
Antenna Beam-width (3 dB) - Azimuth80°
Antenna Beam-width (3 dB) - Elevation40°
Settling Time6 µSec
Pulse Repetition Frequency2 kHz
Operating Temperature-15 °C to 55 °C
Weight8 g
Detection range15–20 m; a wider range may also be possible

Frequently asked questions

What is the detection range of the HB100 microwave sensor module?

The Chinese text gives a detection range of 15–20 m and notes that a wider range may also be possible; a later page states the range exceeds 20 m.

How is the HB100 module connected?

Solder the +5V, GND and IF (signal) pads as marked on the module, and remove the bare wire on the module that protects it from static damage during transport before use.

What supply voltage and current does the module need?

The supply voltage range is 4.75 to 5.25 VDC with 5.00 VDC typical, and current consumption is 30 mA typical, 40 mA maximum.

How is target speed calculated from the Doppler signal?

The document gives Fd = 2v(Ft/c)cos q, where Fd is the Doppler frequency, v the target speed, Ft the transmit frequency, c the speed of light and q the angle; at 10.525 GHz this becomes Fd = 19.49V (km/h).

Download PDF (1 MB)

More HB Manuals


View all HB manuals →