Hanna Instruments HI 9147 Oxycheck Portable Dissolved Oxygen Meter Instruction Manual

Instruction manual for the Hanna Instruments HI 9147 Oxycheck portable dissolved oxygen meter, covering setup, calibration, measurement and maintenance.


Hanna Instruments HI 9147 Oxycheck Portable Dissolved Oxygen Meter Instruction Manual - cover page
Brand
Hanna Instruments
Category
Other Electronics
Document type
User Manual
Language
Portuguese
Pages
2
File format
PDF
File size
155 KB
Published
09 November, 2026
Updated
09 November, 2026
Model
HI 9147
MD5 checksum
19DD4CE94B2C1007D62D33919211B45A

About this manual

The HI 9147 is a waterproof portable dissolved oxygen meter with manual calibration, automatic temperature compensation, salinity compensation and a fixed galvanic probe. Dissolved oxygen readings are shown in mg/L (ppm) or % saturation, and temperature is measured over -5 to 50°C.

The manual explains preliminary checks, controls, specifications, supplied accessories, probe preparation, one-point calibration, measurement, salinity and altitude compensation, probe/membrane maintenance and battery replacement. Two versions are listed: HI 9147-04 with the HI 76409/4 probe (4 m cable) and HI 9147-10 with the HI 76409/10 probe (10 m cable). This manual is written in Portuguese.

What's inside

  • Functional Description
  • Specifications
  • Accessories
  • Probe Preparation
  • Calibration
  • Measurements
  • Salinity Compensation
  • Altitude Compensation
  • Probe and Membrane Maintenance
  • Battery Replacement

Specifications

Dissolved oxygen range0.0 to 50.0 mg/L (ppm) O2
Oxygen saturation range0 to 600% O2
Temperature range-5.0 to 50.0°C
Resolution0.1 mg/L or 1% O2; 0.1°C (1°F)
Accuracy±1% of reading (O2); ±0.2°C (1°F), excluding probe error
CalibrationManual, in saturated air
Temperature compensationAutomatic, 0 to 50°C
Salinity compensation0 to 51 g/L (resolution 1 g/L)
ProbeFixed HI 76409/4 with 4 m cable or HI 76409/10 with 10 m cable
Battery3 x 1.5V AAA
Battery life1000 hours of use (backlight off)
Auto-offAfter approximately 8 minutes
Dimensions185 x 72 x 36 mm
Weight450 g with HI 76409/4 probe

Frequently asked questions

How is the HI 9147 calibrated?

Calibration is manual in saturated air and is a simple one-point procedure.

How often should the probe membrane and electrolyte be replaced?

The manual recommends replacing the membrane every 2 months and the electrolyte once a month.

What happens when the battery level is low?

A flashing “BATT” symbol appears on the LCD to indicate that about 1 hour of operation remains, and the batteries should be replaced as soon as possible.

Can accurate dissolved oxygen readings be taken in still water?

No. The manual states that accurate readings are not possible in still water.