Grundfos SQ SQE Submersible Pump Installation and Operating Instructions

Grundfos SQ and SQE submersible pump installation and operating instructions covering technical data, electrical connection, start-up, operation and fault…


Grundfos SQ SQE Submersible Pump Installation and Operating Instructions - cover page
Brand
Grundfos
Category
AC Submersible Pump Motors
Document type
Installation Guide
Language
English
Pages
22
File format
PDF
File size
2.5 MB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
2B9800DF29B681719028D738B480C298

About this manual

This is the Grundfos installation and operating instructions for the SQ and SQE submersible pumps. It lists the symbols and safety messages used in the document, describes the applications of the SQ, SQE and SQE-NE pumps, and gives the technical data: supply voltage, motor liquid, motor cable, liquid temperature, pump outlet sizes, pump diameter, borehole diameter, installation depth, net weight and storage temperature.

The manual then covers preparation (refilling motor liquid, positional requirements, cooling), electrical connection and motor protection, mechanical installation including assembly of pump part and motor, cable sizing and pipework connection, start-up and operation with diaphragm tank and pressure switch settings, built-in protection, maintenance and service, a fault finding chart, meg ging, checking the power supply, environment and disposal.

What's inside

  • Symbols used in this document
  • General
  • Applications
  • Technical data
  • Storage
  • Sound pressure level
  • Preparation
  • Refilling of motor liquid
  • Positional requirements
  • Liquid temperatures/cooling

Specifications

Supply voltage1 x 200-240 V, -10 %/+6 %, 50/60 Hz, PE
Motor liquidType SML 3
Motor cable1.5 m, 3 x 1.5 mm2, PE
Liquid temperatureMaximum 35 °C
Pump outlet sizeSQ 1, SQ 2, SQ 3: Rp 1 1/4; SQ 5, SQ 7: Rp 1 1/2
Pump diameter74 mm
Borehole diameterMinimum 76 mm
Installation depthMaximum 150 m below static water level
Net weightMaximum 6.5 kg
Storage temperature-20 °C to +60 °C

Frequently asked questions

What liquids are the SQ and SQE pumps designed to pump?

They are designed for pumping thin, clean, non-aggressive, non-explosive liquids that do not contain solid particles or fibres.

What is the maximum temperature of the pumped liquid?

The pumped liquid must not exceed 35 °C; sufficient motor cooling depends on observing this limit.

What is the minimum borehole diameter for the pump?

The borehole diameter must be at least 76 mm (approximately 3").

Can the pump be installed horizontally?

Yes, the pump is suitable for vertical as well as horizontal installation, but the pump shaft must never fall below the horizontal plane.

Which motor liquid is used in the submersible motors?

The motors are factory-filled with Grundfos motor liquid type SML 3, which is frost-proof down to -20 °C.