Grundfos SQ and SQE submersible pump installation and operating instructions covering technical data, electrical connection, start-up, operation and fault…
This is the Grundfos installation and operating instructions for the SQ and SQE submersible pumps. It lists the symbols and safety messages used in the document, describes the applications of the SQ, SQE and SQE-NE pumps, and gives the technical data: supply voltage, motor liquid, motor cable, liquid temperature, pump outlet sizes, pump diameter, borehole diameter, installation depth, net weight and storage temperature.
The manual then covers preparation (refilling motor liquid, positional requirements, cooling), electrical connection and motor protection, mechanical installation including assembly of pump part and motor, cable sizing and pipework connection, start-up and operation with diaphragm tank and pressure switch settings, built-in protection, maintenance and service, a fault finding chart, meg ging, checking the power supply, environment and disposal.
| Supply voltage | 1 x 200-240 V, -10 %/+6 %, 50/60 Hz, PE |
|---|---|
| Motor liquid | Type SML 3 |
| Motor cable | 1.5 m, 3 x 1.5 mm2, PE |
| Liquid temperature | Maximum 35 °C |
| Pump outlet size | SQ 1, SQ 2, SQ 3: Rp 1 1/4; SQ 5, SQ 7: Rp 1 1/2 |
| Pump diameter | 74 mm |
| Borehole diameter | Minimum 76 mm |
| Installation depth | Maximum 150 m below static water level |
| Net weight | Maximum 6.5 kg |
| Storage temperature | -20 °C to +60 °C |
They are designed for pumping thin, clean, non-aggressive, non-explosive liquids that do not contain solid particles or fibres.
The pumped liquid must not exceed 35 °C; sufficient motor cooling depends on observing this limit.
The borehole diameter must be at least 76 mm (approximately 3").
Yes, the pump is suitable for vertical as well as horizontal installation, but the pump shaft must never fall below the horizontal plane.
The motors are factory-filled with Grundfos motor liquid type SML 3, which is frost-proof down to -20 °C.