This manual describes the use, installation and maintenance of the Grundfos Alldos DDI 209 dosing pump.
This manual provides comprehensive installation and operating instructions for the Grundfos DDI 209 diaphragm dosing pump. It covers general information, safety guidelines, technical data, and detailed procedures for installation, electrical connections, and start-up. The document also explains how to use the control unit, perform maintenance tasks like diaphragm replacement, and troubleshoot common faults.
| Dosing flow fluctuation and linearity deviation | ± 1.5 % of the full-scale value |
|---|---|
| Sound pressure level | 45 dB(A) |
| Enclosure class (with mains plug) | IP65 |
| Rated voltage range (AC) | 110-240 V |
| Mains frequency | 50/60 Hz |
| Maximum input power | 20 W |
| Permissible ambient temperature | 0 °C to +40 °C |
| Permissible storage temperature | –10 °C to +50 °C |
The dosing medium must be liquid, non-abrasive, and non-inflammable.
No, the DDI 209 is not approved for operation in potentially explosive areas.