GoodWe EH Series/EH Plus Series 3.6-6kW Hybrid Inverter User Manual

User manual for GoodWe EH Series and EH Plus Series 3.6-6kW hybrid inverters, covering installation, connection, commissioning, and maintenance.


GoodWe EH Series/EH Plus Series 3.6-6kW Hybrid Inverter User Manual - cover page
Brand
Goodwe
Category
inverter
Document type
User Manual
Language
English
Pages
72
File format
PDF
File size
8.6 MB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
252F0B6380CED8EB9108C8D78FA47671

About this manual

GoodWe EH Series/EH Plus Series 3.6-6kW Hybrid Inverter User Manual describes product information, installation, electrical connection, commissioning, troubleshooting, and maintenance. It applies to the listed inverter models: GW3600-EH, GW5000-EH, GW6000-EH, GW3600N-EH, GW5000N-EH, GW5000N-EH-BE, GW5000-EH-BE, and GW6000N-EH.

The document includes safety precautions for general work, PV strings, the inverter, and batteries, as well as personal requirements and an EU Declaration of Conformity. It also covers checking and storage, installation requirements, system wiring, communication connections, power-on checks, SolarGo App settings, SEMS Portal monitoring, maintenance, and technical parameters.

What's inside

  • About This Manual
  • Safety Precaution
  • Product Introduction
  • Check and Storage
  • Installation
  • Electrical Connection
  • Equipment Commissioning
  • System Commissioning
  • Maintenance
  • Technical Parameters

Specifications

Applicable modelsGW3600-EH, GW5000-EH, GW6000-EH, GW3600N-EH, GW5000N-EH, GW5000N-EH-BE, GW5000-EH-BE, GW6000N-EH
GW3600-EH Nominal Output Power3600W
GW5000-EH Nominal Output Power5000W
GW6000-EH Nominal Output Power6000W
GW5000N-EH-BE Nominal Output Voltage230V

Frequently asked questions

Which inverter models does this manual apply to?

It applies to GW3600-EH, GW5000-EH, GW6000-EH, GW3600N-EH, GW5000N-EH, GW5000N-EH-BE, GW5000-EH-BE, and GW6000N-EH.

What should be done before installation?

Read through the user manual to learn about the product and precautions, and have all operations performed by trained and knowledgeable technicians.

What is the recommended specification for additional AC-side protective devices?

The specification should be at least 1.25 times the maximum AC output current.

How long should you wait after power off before components are fully discharged?

Wait 5 minutes after power off until the components are completely discharged.

Download PDF (8.6 MB)