Goldline GL-235 Solar Pool Controller Installation & Operation Manual

The Goldline GL-235 Solar Pool Controller Installation & Operation Manual provides wiring, mounting, setup, and troubleshooting instructions for residential…


Goldline GL-235 Solar Pool Controller Installation & Operation Manual - cover page
Brand
Goldline
Category
Other
Document type
Installation Guide
Language
English
Pages
12
File format
PDF
File size
302 KB
Published
03 October, 2026
Updated
03 October, 2026
Model
GL-235
MD5 checksum
57F86BDE1E7B153D1BE3A99B9828741D

About this manual

This manual explains how to install and operate the Goldline GL-235 solar pool controller. It covers mounting the unit, connecting power, grounding, wiring the low‑voltage solar valve, and configuring high‑voltage outputs for booster pumps or timer overrides. Detailed sensor mounting, freeze‑protection, and nocturnal‑cooling options are also described.

The guide includes wiring diagrams, jumper settings for 12 VAC or 24 VAC valve actuation, and step‑by‑step troubleshooting procedures for power, sensor, and valve faults. Warranty information and safety warnings are provided at the beginning of the document.

What's inside

  • Installation Mounting
  • Power Input
  • Grounding
  • Low Voltage (LV) Output: Solar Valve
  • High Voltage (HV) Output: Booster Pump
  • High Voltage (HV) Output: Timeclock Override
  • Sensor Mounting and Wiring
  • Freeze Protection
  • Nocturnal Cooling
  • Operation

Specifications

Power input voltage105‑130 VAC, .5 A 50/60 Hz or 195‑250 VAC, .3 A 50/60 Hz
Selectable low‑voltage output24 VAC, 20 VA, .85 A or 12 VAC, 20 VA, 1.7 A
High‑voltage output rating115 VAC 1 HP or 240 VAC 2 HP
Sensors requiredTwo 10 kΩ thermistor sensors (10 kΩ @ 25 °C)
Differential temperature controlOn at 4 °F, off at 1.5 °F
Desired pool temperature range70‑104 °F
Recirculate freeze protection activationOn below 40 °F, off above 42 °F

Frequently asked questions

How do I install the GL-235 controller?

Mount the box vertically with the knockouts facing downward, keep it at least 5 feet away from the pool or spa, turn off power at the circuit breaker, remove the internal panel, and follow the wiring diagram for power and sensor connections.

How can I enable recirculate freeze protection?

Install the jumper across both pins marked “RECIRC” on the main circuit board and optionally wire GC‑3 freeze snap switches in series with the collector sensor.

What power input options does the GL-235 support?

The controller can be powered from either 115 VAC or 240 VAC input.

How do I change the valve output to 12 VAC for older valves?

Move jumper J4 on the right side of the circuit board to select the 12 VAC output.