Operator's manual for Gold Line MX4 multiplexer, covering setup, test procedures, and specifications for spatially averaged acoustic measurements.
This manual provides instructions for using the Gold Line MX4 to average microphone inputs from up to four positions. It includes setup steps, microphone placement, gain adjustment, and test procedures using pink noise. The device is compatible with Gold Line RTAs and other analyzers with balanced XLR inputs and time averaging. Specifications cover inputs, outputs, phantom power, and noise performance.
| Inputs | 4 channels, max. level 117dB SPL, typical input impedance 1.2kΩ, noise floor 35dB SPL, CMRR 70dB (60Hz-1kHz), 65dB (20Hz-20kHz) |
|---|---|
| Outputs | 1 channel, active balanced, max. level +10dBu, output impedance 180Ω |
| Phantom Power | 12Vdc, 1.2kΩ x 2 per mic input |
| Frequency Response | 20Hz - 20kHz ±1dB |
| Output Noise | -85dBu (all inputs off) |
Minimum time average for the test should be 20 seconds, and for greatest accuracy we recommend 60 seconds.
Yes, it can be used with all Gold Line 1/3 octave Real Time Analyzers and with most other popular models, provided the RTA has a balanced XLR microphone input.
The MX4 can be provided with three or four model TEF04 reference microphones. If you have a DSP30, use your RTA microphone as the fourth microphone.