Gold Line FD23 Feedback Detector operator's manual describing operation, specifications, and feedback elimination procedures.
The FD23 is a 23-channel feedback detector that helps sound engineers quickly identify feedback frequencies in audio systems. It uses LED indicators for standard ISO third-octave frequencies from 80 Hz to 12.5 kHz and operates via a single on/off/sensitivity control.
The handheld device can be powered by eight AA alkaline or NiCad batteries or an external 12 Vdc supply. The manual includes a step-by-step feedback elimination procedure, specifications, compliance information, and a one-year limited warranty.
| Microphone | Built-in omnidirectional electret condenser |
|---|---|
| Measurement Frequencies | 80, 100, 125, 160, 200, 250, 315, 400, 500, 630, 800, 1k, 1.25k, 1.6k, 2k, 2.5k, 3.15k, 4k, 5k, 6.3k, 8k, 10k, 12.5k Hz |
| Measurement Range | 60 dB - 120 dB |
| Display | Individual LED for each of 23 channels |
| Approvals | Emissions: EN 55022 B, FCC Class B; Immunity: EN 55024 B |
| Power Requirements | Eight AA alkaline or NiCad batteries; external 12 Vdc @ 200 mA via 3.5 mm jack |
| Size | 3.25 x 8 x 2.25 inches |
| Weight | 12 oz |
| Case Material | High impact ABS |
When a frequency is ringing and the sensitivity is set accurately, the LED for that ISO third-octave frequency lights up.
The FD23 can be powered by eight AA alkaline or NiCad batteries, or an external 12 Vdc wall adapter.
The measurement range is 60 dB to 120 dB.