FLIR DM92 true RMS industrial multimeter user manual covering safety, operation, maintenance, and specifications.
This user manual is for the FLIR DM92 true RMS industrial multimeter. It covers safety precautions, meter parts and controls, display information, operating procedures, maintenance, and technical specifications.
The manual also describes features such as a 4000/40000 count dual display, automatic AC/DC selection, VFD mode, low-Z measurement, automatic hold, peak hold, dB/dBm measurement, manual data logging, and CAT IV-600 V/CAT III-1000 V safety ratings. This manual is written in Chinese.
| Maximum voltage | 1000 V DC or 1000 V AC RMS |
|---|---|
| Display count | 4000 / 40000 |
| Power supply | 6 x 1.5 V AAA alkaline batteries |
| Battery life | about 100 hours with backlight and work light off |
| Low battery voltage | about 7.0 V |
| Automatic power off | default 10 minutes |
| Weight | 16.4 oz (465 g) with batteries |
| Dimensions | 2.0 x 3.2 x 7.4 in (52 x 83 x 188 mm) with holster |
| Safety rating | IEC 61010-1 CAT IV-600 V, CAT III-1000 V |
| Fuse rating | 440 mA/1000 V ceramic fast-blow, minimum interrupt rating 10 kA |
It uses six 1.5 V AAA alkaline batteries.
The fuse is rated 440 mA/1000 V ceramic fast-blow with a minimum interrupt rating of 10 kA.
The manual lists CAT IV-600 V and CAT III-1000 V.
The default automatic power-off time is 10 minutes.