FLIR DM92 Manuals

ManualLib has 2 documents for the FLIR DM92 (Other Electronics): 2 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 2

Key facts

Brand
FLIR
Model
DM92
Industry
Electronics
Documents
2
Languages
ZH · EN
Last added
2026-11-21

Start here

FLIR DM92 True RMS Industrial Multimeter User Manual

FLIR DM92 True RMS Industrial Multimeter User Manual

User Manual 31 pages · 1.2 MB · EN

The FLIR DM92 True RMS Industrial Multimeter user manual describes the meter's functions, operation, and maintenance. The introduction lists key features such as a 4000/40 000-count dual display, auto AC/DC selection in voltage and current modes, variable-frequency drive mode with low-pass filter, 0.05% DCV accuracy, Low-Z measurement, auto hold, peak hold, dB/dBm measurement, a 99-record data memory, and CAT IV-600 V / CAT III-1000 V safety rating.

The manual explains function switch positions, function buttons, display icons, and measurement procedures for voltage, resistance, continuity, diode, capacitance, Type K temperature, and current. It also covers extended functionality, hold modes, cleaning and storage, battery and fuse replacement, general specifications, electrical range specifications, technical support, and warranties.

Read online

FLIR DM92 specifications

Maximum voltage1000 V DC or 1000 V AC RMS
Display count4000 / 40000
Power supply6 x 1.5 V AAA alkaline batteries
Battery lifeabout 100 hours with backlight and work light off
Low battery voltageabout 7.0 V
Automatic power offdefault 10 minutes
Weight16.4 oz (465 g) with batteries
Dimensions2.0 x 3.2 x 7.4 in (52 x 83 x 188 mm) with holster
Safety ratingIEC 61010-1 CAT IV-600 V, CAT III-1000 V
Fuse rating440 mA/1000 V ceramic fast-blow, minimum interrupt rating 10 kA

Source: FLIR DM92 True RMS Industrial Multimeter User Manual

All FLIR DM92 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What batteries does the FLIR DM92 use?

It uses six 1.5 V AAA alkaline batteries.

From: FLIR DM92 True RMS Industrial Multimeter User Manual

What is the fuse rating?

The fuse is rated 440 mA/1000 V ceramic fast-blow with a minimum interrupt rating of 10 kA.

From: FLIR DM92 True RMS Industrial Multimeter User Manual

What safety category rating does the FLIR DM92 have?

The meter has a safety category rating of CAT IV-600 V and CAT III-1000 V.

From: FLIR DM92 True RMS Industrial Multimeter User Manual

What type of batteries does the meter use?

It uses six 1.5 V AAA alkaline batteries.

From: FLIR DM92 True RMS Industrial Multimeter User Manual