Key facts
- Brand
- FLIR
- Model
- DM92
- Category
- Other Electronics
- Industry
- Electronics
- Documents
- 2
- Languages
- ZH · EN
- Last added
- 2026-11-21
Start here

FLIR DM92 True RMS Industrial Multimeter User Manual
The FLIR DM92 True RMS Industrial Multimeter user manual describes the meter's functions, operation, and maintenance. The introduction lists key features such as a 4000/40 000-count dual display, auto AC/DC selection in voltage and current modes, variable-frequency drive mode with low-pass filter, 0.05% DCV accuracy, Low-Z measurement, auto hold, peak hold, dB/dBm measurement, a 99-record data memory, and CAT IV-600 V / CAT III-1000 V safety rating.
The manual explains function switch positions, function buttons, display icons, and measurement procedures for voltage, resistance, continuity, diode, capacitance, Type K temperature, and current. It also covers extended functionality, hold modes, cleaning and storage, battery and fuse replacement, general specifications, electrical range specifications, technical support, and warranties.
FLIR DM92 specifications
| Maximum voltage | 1000 V DC or 1000 V AC RMS |
|---|---|
| Display count | 4000 / 40000 |
| Power supply | 6 x 1.5 V AAA alkaline batteries |
| Battery life | about 100 hours with backlight and work light off |
| Low battery voltage | about 7.0 V |
| Automatic power off | default 10 minutes |
| Weight | 16.4 oz (465 g) with batteries |
| Dimensions | 2.0 x 3.2 x 7.4 in (52 x 83 x 188 mm) with holster |
| Safety rating | IEC 61010-1 CAT IV-600 V, CAT III-1000 V |
| Fuse rating | 440 mA/1000 V ceramic fast-blow, minimum interrupt rating 10 kA |
Source: FLIR DM92 True RMS Industrial Multimeter User Manual
All FLIR DM92 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What batteries does the FLIR DM92 use?
It uses six 1.5 V AAA alkaline batteries.
What is the fuse rating?
The fuse is rated 440 mA/1000 V ceramic fast-blow with a minimum interrupt rating of 10 kA.
What safety category rating does the FLIR DM92 have?
The meter has a safety category rating of CAT IV-600 V and CAT III-1000 V.
What type of batteries does the meter use?