Ferroxcube 3E7 Material Specification Data Sheet

This datasheet details the specifications for Ferroxcube 3E7 high permeability material, optimized for wideband transformers with low losses.


Ferroxcube 3E7 Material Specification Data Sheet - cover page
Brand
FERROXCUBE
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
4
File format
PDF
File size
43 KB
Published
16 October, 2026
Updated
16 October, 2026
MD5 checksum
B3ABC771A4CB5035D13C4A76B57F230F

About this manual

This document provides a technical specification for the Ferroxcube 3E7 material, a high permeability ferrite designed for wideband transformers where small size or a low number of turns are critical design parameters. The material is optimized for applications requiring high permeability and low losses across a wide frequency range.

The datasheet lists key performance characteristics measured on sintered, non-ground ring cores, including initial permeability, loss tangent, and temperature coefficient of permeability. It also includes graphical representations of complex permeability versus frequency, initial permeability versus temperature, typical B-H loops, and reversible permeability versus magnetic field strength.

What's inside

  • Specifications
  • Conditions
  • Complex permeability
  • Initial permeability
  • B-H loops
  • Reversible permeability
  • Status Definitions
  • Disclaimer

Specifications

Initial permeability (µi)15000 ± 20%
Saturation flux density (B2)≈ 390 mT
Temperature coefficient of permeability (TC)≥ 130 °C
Density≈ 4900 kg/m3
Resistivity (ρ DC)≈ 0.1 Ωm

Frequently asked questions

What is the primary application for Ferroxcube 3E7?

It is optimized for use in wideband transformers where small size or a low number of turns are important design parameters.

What are the test conditions for the initial permeability?

The initial permeability is measured at 25°C, ≤10 kHz, and 0.25 mT.

Is this material suitable for life support applications?

No, these products are not designed for use in life support appliances, devices, or systems where malfunction can result in personal injury.