The PTX 600 Series pressure transmitters are two‑wire, 4‑20 mA output devices designed for critical industrial and research applications. They feature a miniature micro‑machined silicon sensor sealed in a glass‑to‑metal assembly with a Hastelloy C276 diaphragm, delivering high accuracy (±0.08 % FS BSL) and long‑term stability (±0.1 % FS per year).

The datasheet outlines the full pressure range (1.5 – 10 000 psi), supply voltage (9‑30 V DC), intrinsic safety classifications, and available electrical and pressure connection options. Detailed mechanical, electrical, and environmental specifications are provided to aid installation, calibration, and maintenance.

What's inside

  • Features
  • Operating Pressure Range
  • Technical Specifications
  • Electrical Connections
  • Installation Information
  • Accessories
  • Calibration
  • Safety and Intrinsic Safety

Specifications

Accuracy±0.08 % FS BSL
Supply Voltage9‑30 V DC
Output Current4‑20 mA (2‑wire)
Pressure Range1.5 – 10 000 psi (gauge & absolute)
Temperature Range (ambient)-5 °F to +175 °F
Intrinsic SafetyClass I, Div. 1, Groups A‑D
Weight (core only)12 oz

Frequently asked questions

What is the supply voltage range for the PTX 600 series?

The transmitter operates from 9 V to 30 V DC.

What output signal does the PTX 600 series provide?

It provides a 4‑20 mA current loop output in a two‑wire configuration.

What pressure ranges are covered by the PTX 600 series?

The devices cover pressures from 1.5 psi up to 10 000 psi, with both gauge and absolute options.

Is the PTX 600 series intrinsically safe for hazardous areas?

Yes, it is intrinsically safe Class I, Division 1, Groups A‑D.