The Chen Zhu CZ3076.R/CZ3079.R Isolator User Manual provides installation, wiring, maintenance, and technical parameters for the potentiometer input isolator.
The Chen Zhu CZ3076.R/CZ3079.R Isolator converts two-wire or three-wire potentiometer signals into isolated 0/4–20 mA current or 0/1–5 V voltage output. It is an intelligent device whose measuring range can be set through a computer using EasyConfig configuration software.
The product requires an independent power supply, with power, input, and output isolated from each other. It mounts on a DIN35mm standard rail and provides alarm indications for low-range, high-range, and broken-wire conditions. This manual is written in Chinese.
| Channels | 1/2 (CZ3076.R); 2 (CZ3079.R) |
|---|---|
| Supply voltage | 20–35V DC |
| Temperature drift | 0.01%F.S./℃ |
| Response time | 1s to 90% of final value |
| Insulation strength | 1500V AC, 1 minute |
| Insulation resistance | ≥100MΩ at 500V DC |
| Weight | About 150g |
| Operating temperature | -20℃ to +60℃ |
It requires 20–35V DC independent power; 220V AC power is strictly prohibited.
It is mounted using a DIN35mm standard rail by hooking the top and pushing the bottom into place.
It provides isolated 0/4–20 mA current output or 0/1–5 V voltage output.
The product is repaired free of charge by Chen Zhu for quality problems within five years from shipment under normal use.