About this manual

The Chenzhu Instrument A55 and A56 are isolated safety barriers designed for connecting intrinsically safe instruments in hazardous zones (Zone 0/1/2) to safe area equipment. The A55 model converts thermocouple or RTD signals into digital RS485 output using the MODBUS-RTU protocol, while the A56 model converts these signals into a standard 4~20mA current loop signal.

Both models feature two relay outputs for alarm setting based on user-defined limits. They support various temperature sensors including Pt100, Cu50/Cu100, and thermocouples (T, E, J, K, N, R, S, B). The devices are housed in a Phoenix Contact GS8500 series plastic enclosure and carry NEPSI explosion-proof certification for Class II C/B/A environments. This manual is written in Chinese.

What's inside

  • Product Description
  • Technical Specifications
  • RS485 Output (A55)
  • Current Output (A56)
  • Relay Alarm Outputs
  • Input Signal Types
  • Explosion-Proof Certification
  • Installation and Wiring

Specifications

Supply Voltage20~35V DC
Consumption Current (A55)≤35mA
Communication ProtocolMODBUS-RTU
Max Communication Distance≤1000m
Max Slave Quantity≤32
Relay Drive Capability250V AC, 2A or 30V DC, 2A
Measurement Error (Typical)0.05%F.S.
Operating Temperature-20℃~+60℃
Insulation Strength (Safe to Intrinsic)≥2500V AC
WeightAbout 150g

Frequently asked questions

What temperature sensors are supported by the A55 and A56?

The devices support RTDs (Pt100, Cu50, Cu100) and thermocouples (T, E, J, K, N, R, S, B).

What is the communication protocol for the A55 model?

The A55 uses the MODBUS-RTU bus protocol with a default address of 1.

What is the explosion-proof rating for these barriers?

They are certified with an explosion-proof mark of [Ex ia Ga] II C.

What is the default alarm limit range?

The default lower limit is 3.8mA and the upper limit is 20.8mA.