The Chenzhu Instrument A55 and A56 are isolated safety barriers designed for connecting intrinsically safe instruments in hazardous zones (Zone 0/1/2) to safe area equipment. The A55 model converts thermocouple or RTD signals into digital RS485 output using the MODBUS-RTU protocol, while the A56 model converts these signals into a standard 4~20mA current loop signal.
Both models feature two relay outputs for alarm setting based on user-defined limits. They support various temperature sensors including Pt100, Cu50/Cu100, and thermocouples (T, E, J, K, N, R, S, B). The devices are housed in a Phoenix Contact GS8500 series plastic enclosure and carry NEPSI explosion-proof certification for Class II C/B/A environments. This manual is written in Chinese.
| Supply Voltage | 20~35V DC |
|---|---|
| Consumption Current (A55) | ≤35mA |
| Communication Protocol | MODBUS-RTU |
| Max Communication Distance | ≤1000m |
| Max Slave Quantity | ≤32 |
| Relay Drive Capability | 250V AC, 2A or 30V DC, 2A |
| Measurement Error (Typical) | 0.05%F.S. |
| Operating Temperature | -20℃~+60℃ |
| Insulation Strength (Safe to Intrinsic) | ≥2500V AC |
| Weight | About 150g |
The devices support RTDs (Pt100, Cu50, Cu100) and thermocouples (T, E, J, K, N, R, S, B).
The A55 uses the MODBUS-RTU bus protocol with a default address of 1.
They are certified with an explosion-proof mark of [Ex ia Ga] II C.
The default lower limit is 3.8mA and the upper limit is 20.8mA.