Chenzhu GS8552-EX.11 Frequency Input Isolation Safety Fence User Manual

GS8552-EX.11 is a frequency input isolation safety fence produced by Chenzhu Electric. It has 12V power supply and provides isolation power for field instruments in dangerous areas. The explosion-proof certificate number is GYB15.1729.


Chenzhu GS8552-EX.11 Frequency Input Isolation Safety Fence User Manual - cover page
Brand
Chenzhu
Category
Industrial Supply
Document type
User Manual
Language
Chinese
Pages
2
File format
PDF
File size
784 KB
Published
29 October, 2023
Updated
29 October, 2023
MD5 checksum
C3AA0A321E4BB5BA3165F050087AABFA

About this manual

The Chenzhu GS8552-EX.11 is a frequency input isolation safety fence designed to provide isolated power to field instruments in hazardous areas and transmit frequency signals to the safe side. It features independent power, input, and output isolation with a hysteresis comparison circuit for high anti-interference performance. The device supports 12V or 5V distribution and is suitable for use in Ex ia Ga hazardous environments (Zone 0, 1, 2). This manual is written in Chinese.

What's inside

  • Installation
  • Wiring
  • Maintenance
  • Operating Environment
  • Application
  • Technical Specifications
  • Safety Certification
  • Output Characteristics

Specifications

Power Supply Voltage20~35V DC
Operating Temperature-20℃~+60℃
Storage Temperature-40℃~+80℃
Relative Humidity10%~90%
Insulation Strength (Non-Intrinsic to Intrinsic)≥2500V AC
Insulation Resistance (Non-Intrinsic to Intrinsic)≥100MΩ
WeightAbout 150g
Dimensions (Depth x Height x Width)118.9mm x 106.0mm x 17.5mm
Explosion Protection MarkingEx ia Ga

Frequently asked questions

What is the maximum operating temperature for the Chenzhu GS8552-EX.11?

The continuous operating temperature range is from -20℃ to +60℃.

Can the Chenzhu GS8552-EX.11 be used in Zone 0 hazardous areas?

Yes, it can be installed in safe areas and connected to intrinsically safe instruments in Zone 0, Zone 1, and Zone 2 hazardous locations.

What is the recommended wire insulation strength for the Intrinsic Safety side?

The insulation strength of the wiring on the Intrinsic Safety side should be greater than 500V.

Is it allowed to use a Megger to test the insulation between terminals of the safety fence?

No, using a Megger to test the insulation between terminals is strictly prohibited as it may cause internal fast fuses to blow.