Celduc PXS79 Coded Magnetic Safety Switch Product Leaflet

Celduc PXS79 coded magnetic safety switches for machine protection, with UL/cULus certification and Cat. 4/PL=e/SIL 3 capability.


Celduc PXS79 Coded Magnetic Safety Switch Product Leaflet - cover page
Brand
CELDUC
Category
sensor
Document type
Product Leaflet
Language
French
Pages
6
File format
PDF
File size
439 KB
Published
10 November, 2026
Updated
10 November, 2026
MD5 checksum
1F0814FB6A5EB57D59BFC16DA2EB85D4

About this manual

The Celduc PXS79 is a coded magnetic switch (safety sensor) designed for machine protection and reliability. It is available in versions with or without an LED and serial resistance, with 2 m, 5 m, or 10 m cables or an M8 connector.

With an appropriate monitoring system and correct wiring, it can reach Cat. 4 / PL=e per EN/ISO 13849-1 and SIL 3 per IEC 61508. The leaflet lists rated electrical characteristics, mounting clearances, cable connection procedures, and ordering references. This manual is written in French.

What's inside

  • Dimensions
  • Characteristics
  • Rated operating characteristics
  • Cable connection
  • Ordering references
  • Available references
  • Mounting clearances
  • Typical application

Specifications

StandardsIEC 60947-5-1, EN/ISO 12100, EN 60204, EN 1088 / EN ISO 14119
CertificationsUL/cULus
Ambient air temperature (operation)-25 to 85 °C (-13 to 185 °F)
Ambient air temperature (storage)-40 to 85 °C (-40 to 185 °F)
Rated operating characteristicsWith LED/10 Ω: 24 V DC, 100 mA; without LED/0 Ω: 24 V DC, 400 mA
Required fuse500 mA gG (gl) cartridge fuse
Operating cycle frequency150 Hz
B10d20 million cycles at 24 V DC, 10 mA
Drop-out voltage0.1 V DC without LED at 10 mA; 2.4 V DC with LED and 10 Ω at 10 mA; 1 V DC without LED at 100 mA; 4.2 V DC with LED and 10 Ω at 100 mA
Cable connection4 conductors; minimum 0.25 mm² (24 AWG); lengths 2 m, 5 m, 10 m or M8 connector
Maximum ratings0.4 A, 100 V DC, 10 VA
Contacts2 NC switches (closed with coded magnet)

Frequently asked questions

What safety performance level can the PXS79 reach?

With an appropriate monitoring system and correct wiring, it can reach Cat. 4 / PL=e per EN/ISO 13849-1 and SIL 3 per IEC 61508.

What certifications do the PXS79 switches have?

They have obtained UL/cULus certifications.

What cable lengths and connector options are available?

Typical cable lengths are 2 m, 5 m, and 10 m, or an M8 connector.

What is the minimum conductor wire size for cable connection?

The minimum conductor wire size is 0.25 mm² (24 AWG).