Celduc SA842070 Power Solid State Relay User Manual

Power Solid State Relay with internal voltage protection, output range is 12-275VAC 25A, input range is 3-32VDC, with current limiter, can be applied to motors, lamps, heaters and other equipment.


Celduc SA842070 Power Solid State Relay User Manual - cover page
Brand
CELDUC
Document type
User Manual
Language
English
Pages
6
File format
PDF
File size
639 KB
Published
16 February, 2012
Updated
30 September, 2023
MD5 checksum
24797B2F1F1831849D7F4AF50311BE3C

About this manual

This manual describes the Celduc SA842070 solid‑state relay, including its electrical characteristics, control voltage range (3‑32 VDC) and output capability (12‑275 VAC, 25 A). It also covers protection features such as internal voltage protection, input over‑voltage protection, and IP20 transparent cover options.

Installation guidance includes recommended wiring methods, torque specifications, and the requirement to mount the relay on a heatsink using thermal grease. Thermal performance curves and heatsink selection are provided to ensure reliable operation under various ambient temperatures and duty cycles.

What's inside

  • Control characteristics
  • Output characteristics
  • Thermal curves and heatsink choice
  • Connections and wiring
  • Mounting instructions
  • Protection and safety
  • EMC and immunity
  • General specifications

Specifications

Input voltage range3‑32 VDC
Output voltage range12‑275 VAC
Rated current25 A
On‑state voltage drop (25 °C)0.85 V
Zero‑cross level20 V
Input‑to‑output insulation4000 VRMS
Weight85 g
Ambient temperature range-40 °C to 48 °C
Storage temperature range-40 °C to 125 °C

Frequently asked questions

What is the input voltage range for the SA842070 SSR?

The relay operates with an input voltage between 3 VDC and 32 VDC.

What is the maximum output current the SA842070 can handle?

It is rated for a continuous output current of 25 A.

How should the SA842070 be mounted?

The SSR must be mounted on a heatsink and thermal grease should be applied between the device and the heatsink.

What protection features are included in the SA842070?

It includes input over‑voltage protection, internal voltage protection, and optional IP20 transparent cover for touch protection.

Download PDF (639 KB)