Celduc ESUC0450 Current Monitoring Module Datasheet

Celduc ESUC0450 current monitoring module for SU/SUL solid state relays monitors up to five heating loads and detects open load, shorted SSR and leakage…


Celduc ESUC0450 Current Monitoring Module Datasheet - cover page
Brand
CELDUC
Category
Other Electronics
Document type
Datasheet
Language
French
Pages
9
File format
PDF
File size
1.5 MB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
901614504465B0D99098D55C5D063134

About this manual

Celduc ESUC0450 is a current monitoring module used with celduc SU/SUL solid state relays. It monitors one or more heating loads, up to five in parallel, and detects open mains, open load, partial load break, short-circuited SCR and leakage current.

The module learns the teach current through the TEACH pushbutton or an external teach input. It uses an alarm threshold of 0.84 times the teach current and indicates faults through a diagnostic output and LEDs. Control characteristics, teaching sequences and wiring diagrams are included. This manual is written in French.

What's inside

  • Function mode diagram
  • Product description
  • Teaching mode diagram
  • Summary of diagnostic function
  • Control characteristics
  • Wiring diagram with several modules
  • Characteristics

Specifications

Current range2-40 A
Supply voltage8-30 VDC
Diagnostic output8-30 VDC, 0.1 A
Alarm threshold0.84 x teach current (-16%)
Maximum loads5 heating loads
Protection ratingIP20
ConformityEN60947-4-3
Teach current range2-40 A rms
Short activation<2 s (test mode)
Long activation>3 s (teach mode)

Frequently asked questions

What is the alarm threshold?

The alarm threshold is 0.84 times the teach current (-16%).

How many heating loads can the module monitor?

It can monitor up to five heating loads switched by a standard celduc solid state relay.

How is the teach current recorded?

Press or activate the TEACH pushbutton or external teach input for more than 3 seconds.

What happens if the teach current is outside the 2-40 A range?

The green INPUT and yellow ON LEDs flash alternately to indicate that diagnosis is impossible.

Download PDF (1.5 MB)

More CELDUC Manuals