Carlo Gavazzi ESI electromagnetic safety interlock manual for separated actuator, covering safety, features, technical data, installation, and keys.
This instruction manual is for the Carlo Gavazzi ESI electromagnetic safety interlock with a separated actuator. It says the safety switches are designed and manufactured in accordance with IEC international standards and EN European regulations, and are used on machines where hazardous conditions remain after stop signal generation.
The manual covers safety, features, technical data, types of interlock, installation, dimensions, and keys. It states that functional safety is guaranteed for the product as a single component, but the overall system safety level must be defined through risk analysis.
| Maximum actuating speed | 20 m/min |
|---|---|
| Retention force at locked actuator | 1200N |
| Rated operating current | AC-15 24V - 10A |
| Operating temperature | -25 ÷ 55°C |
| Protection degree | IP65 |
The interlock is built to SIL 3, PL e, and interlock type 2 in accordance with applicable standards.
A safety assessment in accordance with the Machinery Directive must be performed before use.
The device allows immediate access to the protected area if there is a lack of voltage.