Carlo Gavazzi DCT1 Direct Connection Energy Transducer User Manual

Carlo Gavazzi DCT1 user manual: a direct connection energy transducer for DC systems up to 1000 Vdc and 600 Adc, with Modbus RTU or SML communication.


Carlo Gavazzi DCT1 Direct Connection Energy Transducer User Manual - cover page
Brand
CARLO GAVAZZI
Category
Analyzer
Document type
User Manual
Language
English
Pages
126
File format
PDF
File size
1 MB
Published
07 November, 2026
Updated
07 November, 2026
MD5 checksum
13BF2887A22EC77F6B2BB4A5FF01D783

About this manual

This user manual covers the Carlo Gavazzi DCT1, a direct connection energy transducer for DC systems up to 1000 Vdc with current up to 600 Adc. It explains the layout of the front and back of the unit, the available part numbers, the evaluation certificate, and the UCS configuration software that connects to the device over RS485 using the Modbus RTU protocol.

The manual describes use and commissioning: maintenance mode and cable loss compensation, the parameters that can be set through UCS or Modbus commands, reset commands, Modbus RTU and SML communication, run-hour meters, temperature monitoring, easy connection, and maintenance and disposal. Troubleshooting of communication problems and cleaning instructions are also included.

What's inside

  • Introduction
  • Available versions
  • Evaluation certificate
  • Configuration software
  • Maintenance mode and cable loss compensation
  • Settings
  • Reset
  • Commissioning
  • Easy connection
  • Temperature monitoring

Specifications

Voltage range150...1000 Vdc
Current range6-120 (600) A (versions DCT1A60...); 2.5-50 (300) A (versions DCT1A30...)
Communication protocolsModbus RTU, Modbus RTU with 256-bit or 384-bit signature, or SML with 384-bit signature
Configuration softwareUCS, desktop version, connects via RS485 (Modbus RTU)
Cable loss parameter changes on certified modelsMaximum 50 times (part numbers ending with "EC")

Frequently asked questions

What is the Carlo Gavazzi DCT1?

It is a direct connection energy transducer for DC systems up to 1000 Vdc and current up to 600 Adc.

Which communication protocols does the DCT1 support?

Modbus RTU, Modbus RTU with either a 256-bit or 384-bit signature, or SML with a 384-bit signature, depending on the version.

Which software is used to configure the DCT1?

UCS, the DCT1 configuration software, is available in a desktop version and connects to the unit via RS485 using Modbus RTU.

How many times can the cable loss parameter be changed on certified models?

On certified models, whose part numbers end with "EC", the parameter can only be changed 50 times.

Download PDF (1 MB)