IO-Link data map for Banner Engineering Q4X sensors, covering communication parameters, process data in, parameters and events.
This IO-Link Data Reference Guide covers the Banner Engineering Q4X laser sensor. It refers to the IODD file Banner_Engineering-Q4X-20150313-IODD1.1.xml for the 100/110 mm and 300/310 mm models, and Banner_Engineering-Q4X-600mm-20161205-IODD1.1.xml for the 600/610 mm models. The original document is 198185 Rev. E.
The guide lists the IO-Link communication parameters, the 16-bit Process Data In layout sent from the device to the master, and the acyclic parameters that can be read or written, including setpoints, configuration, status and statistics. It also lists IO-Link event codes. Process Data Out is not applicable.
| IO-Link revision | V1.1 |
|---|---|
| Process Data In length | 16 bits |
| Process Data Out length | N/A |
| Bit rate | 38400 bps |
| Minimum cycle time | 2.7 ms |
| Port class | A |
| Measurement value resolution | Tenths of a millimeter |
The Q4X uses IO-Link revision V1.1.
The process data is sent to the IO-Link master every 2.7 ms.
It includes the measurement distance, the stability indicator state and the state of both Q4X output channels.
It is an error event with code 36096 (0x8d00) indicating the laser shut down for safety.