About this manual

This document is a datasheet for the Balluff BES018Y sensor, order number BES 516-3019-S4-C. It lists electrical, environmental, mechanical, and functional-safety data for the device.

The sensor has a PNP normally closed switching output, a 4 mm rated operating distance, an M12x1 four-pole A-coded connector, and an IP68 protection type. Its housing is stainless steel and its sensing surface is LCP.

What's inside

  • Display/Operation
  • Electrical connection
  • Electrical data
  • Environmental conditions
  • Functional safety
  • General data
  • Mechanical data
  • Output/Interface
  • Range/Distance
  • Remarks

Specifications

Function indicatoryes
Power indicatorno
ConnectionM12x1-Connector, 4-pole, A- coded
Polarity reversal protectedyes
Short-circuit protectionyes
Hysteresis H max. (% of Sr)15.0 %
Load capacitance max. at Ue0.5 µF
MTTF (40 °C)640 a
No-load current lo max., undamped6 mA
Operating voltage Ub10…30 VDC
Output resistance Ra33.0 kOhm + D
Pollution degree3
Protected against miswiringyes
Rated insulation voltage Ui250 V AC
Rated operating current Ie DC200 mA
Rated operating voltage UeDC 24 V
Rated short circuit current100 A
Ready delay tv max.21 ms
Repeat accuracy max. (% of Sr)5.0 %
Residual current Ir max.10 µA
Switching frequency2500 Hz
Utilization categoryDC -13
Voltage drop static max.2.5 V
Ambient temperature-40…85 °C
Protection classII
Protection typeIP68 (IEC 60529)
Diagnostic coverage0 %
Functional safetyno
Mission Time20 a
Approval/ConformitycULus, DC, Code 81U2 CE EAC
Basic standardIEC 60947-5-2
Housing materialStainless steel
Material sensing surfaceLCP
DimensionØ 12 x 70 mm
Installationnon-flush
SizeM12x1
Tightening torque12 Nm
Switching outputPNP Normally closed (NC)
Assured operating distance Sa3.2 mm
Range4 mm
Rated operating distance Sn4 mm
Ripple max. (% of Ue)15 %
Temperature drift max. (% of Sr)10 %

Frequently asked questions

What is the operating voltage of the Balluff BES018Y sensor?

The operating voltage (Ub) is 10…30 VDC.

What is the rated operating distance?

The rated operating distance (Sn) is 4 mm.

What type of switching output does it have?

It has a PNP normally closed (NC) switching output.

What is the protection type?

The protection type is IP68 according to IEC 60529.

Download PDF (220 KB)