Balluff BF-IDU03 RFID-Reader Operating Guide

This document is the operating guide of BF-IDU03 RFID-Reader. It introduces the purpose and function of the device, including the reading and writing data process, as well as the things to be noticed during use.


Balluff BF-IDU03 RFID-Reader Operating Guide - cover page
Brand
Balluff
Document type
User Manual
Language
English
Pages
4
File format
PDF
File size
243 KB
Published
17 October, 2023
Updated
17 October, 2023
MD5 checksum
38F71B882DDCA584879C308FEDAF6C9C

About this manual

This guide explains how to operate the Balluff BF-IDU03 RFID reader, including connection to a BIS V control unit and compliance with regional regulations. It details status indicators, electrical specifications, and mounting requirements. The device reads and writes EPC Global Class 1 Gen2 tags via UHF frequencies, with power and control managed through the connected control unit.

What's inside

  • Purpose of the Device
  • Check Device Variant
  • Connecting the Device
  • Mounting
  • Setup and Operation
  • Status Indicators
  • Electrical Data
  • Mechanical Data

Specifications

Operating Voltage19.2…28.8 V DC
Current Draw≤ 200 mA
Maximum Read Range1000 mm
Antenna Beam Opening Angle90° (horizontal/vertical)
Housing MaterialMetal / ABS / PC
Weight850 g
Ambient Temperature Range-20°C .. +55°C
Device Size130 mm x 130 mm x 50.5 mm

Frequently asked questions

What is the BF-IDU03 device intended to do?

The device is intended to read and write EPC Global Class 1 Gen2 compliant data carriers via country dependent UHF radio frequencies.

How should the device be mounted?

The device must be fixed mounted with at least 2 screws of M4 or M5 size in mounting holes at the back side.

What is the minimum distance required between the antenna and the workplace?

The minimum distance between the UHF antenna and the workplace must be 25 cm.

What is the maximum read range of the device?

The maximum read range is 1000 mm.