Anderson-Negele MAN-90-BAT LCD manometer and pressure switch for hygienic process pressure control in food and pharma applications.
The Anderson-Negele MAN-90-BAT and MAN-90P-BAT are LCD manometers and pressure switches for hygienic process pressure control in food and pharma applications. They feature a 23 mm display, IP 66 sealed housing, two-fold overpressure safety, and CLEANadapt process connections; the MAN-90P-BAT pharma version has a membrane surface roughness of Ra ≤ 0.2 µm and meets ASME BPE requirements.
The document provides technical data, dimensions and electrical connections, display and operation, programming of setpoints and calibration, cleaning and storage notes, accessories, and the ordering code. Optional two independent switching relays with external power supply are available, and the device is not suitable for explosive atmospheres or SIL safety-related parts. This manual is written in German.
| Membrane material | 316L; optional Hastelloy C |
|---|---|
| Process connection and housing material | 1.4404 / 1.4301, fully welded |
| Sight glass | Polysulfon, temperature-resistant to 163 °C |
| Membrane surface roughness | Ra ≤ 0.6 µm (standard) |
| Transfer fluid | Paraffin oil / medical white oil |
| Protection rating | IP 66 / NEMAX 4X |
| Overpressure stability | 2-fold |
| Accuracy | 0.2 % of full scale |
| Reproducibility | ±0.06 % of full scale |
| Linearity | ±0.07 % of full scale |
| Hysteresis | ±0.07 % of full scale |
| CIP/SIP cleaning | 149 °C for max. 60 minutes |
| Temperature drift | < ±0.16 % / 10 K of full scale |
| Display digit height | 23 mm |
| Power supply (LCD) | 2 x AA batteries |
| Power supply (relays) | 9...30 V DC, 250 mA |
| Relay output | 2 switching relays, max. 24 V DC, 1 A |
| Weight | 830 g (CLEANadapt G1"), 690 g (Tri-Clamp 1.5"), 710 g (Tri-Clamp 2"), +50 g (rear connection) |
| MAN-90P-BAT standards | Meets ASME BPE requirements |
The accuracy is 0.2 % of the full scale value.
It has protection rating IP 66 / NEMAX 4X.
CIP/SIP cleaning is possible up to 149 °C for a maximum of 60 minutes.
The relay contacts require 9...30 V DC at 250 mA.