This document is the installation and operating instructions for Anderson-Negele's Bolt-on Weighing Cells L-Cell® and Microcell®. It describes how to install, use, and maintain these two series of weighing sensors.
This document provides detailed installation and operating instructions for Anderson-Negele's L-Cell® and Microcell® bolt-on weighing cells. It covers preparation, mounting on vertical legs, horizontal beams, and skirted silos, wiring junction boxes, system calibration, and troubleshooting. The guide is intended for qualified service personnel and includes technical specifications for both sensor types.
The L-Cell® is designed for carbon steel and aluminum structures, while the Microcell® offers standardized and non-standardized options. Both sensors operate within a wide temperature range and feature specific excitation and output characteristics. Safety precautions, including grounding during welding, are emphasized to prevent damage.
| Fatigue Life (L-Cell®) | > 20 million cycles; load & unload at 0 to 7,500 psi (0 to 5.3 kg/mm²) |
|---|---|
| Zero Strain Output | 0 mV ± 100 mV |
| Cable | 3-conductor, 22 gauge, unshielded (15" (4.6 m)) |
| Fatigue Life (Microcell®) | > 20 million cycles; load & unload at 0 to 5,000 psi (0 to 3.5 kg/mm²) |
| Zero Strain Output (Microcell®) | 0 mV ± 100 mV |
| Cable (Microcell®) | 3-conductor, 22 gauge, unshielded (15" (4.6 m)) |
The L-Cell can operate in temperatures ranging from -34 to 66 °C (-30 to 150 °F).
The maximum stress level for an aluminum L-Cell structure is ± 6,500 psi (4.6 kg/mm²).