Safety Data Sheet for the Agilent GKK-407 Sialic Acid Labeling Kit, detailing components, hazards, and handling instructions.
This document is a Safety Data Sheet (SDS) for the Agilent GKK-407 Sialic Acid Labeling Kit. The kit is a multi-level product containing specific chemical modules including Reaction Solution (Vials WS0028), Reducing Agent (Vials WS0029), DMB Dye (Vials WS0030), Release Agent (Vials WS0031), and Sialic Acid Reference Mix (Vials WS0032). The primary focus of the document is the safety information for the Reaction Solution component, which contains acetic acid and 2-mercaptoethanol. This manual is written in Chinese.
| Kit Part Number | GKK-407 |
|---|---|
| Reaction Solution Volume | 300 µl |
| Reducing Agent Quantity | 1.5 mg |
| DMB Dye Quantity | 0.4 mg |
| Release Agent Volume | 1.5 ml |
| Sialic Acid Reference Mix Quantity | 1.25 nmol |
| Boiling Point | 100 °C |
| Vapor Pressure at 20 °C | 23 hPa |
| Density at 20 °C | 1.00994 g/cm³ |
The kit includes Reaction Solution, Reducing Agent, DMB Dye, Release Agent, and Sialic Acid Reference Mix.
The solution is harmful if swallowed, causes skin irritation, serious eye irritation, and may cause sensitization by skin contact.
Open the eyes and rinse under running water for several minutes. If symptoms persist, consult a doctor.