Installation and user guide for AEG GYB00416DT/GYB00816DT water heater systems, covering components, setup, troubleshooting, and technical specs.
This manual provides step-by-step instructions for installing and operating the AEG GYB00416DT/GYB00816DT water heater systems. It includes diagrams of main components, setup for single and combined configurations, and troubleshooting for common issues like no water flow or overheating. Technical specifications cover electrical requirements, water pressure, flow rates, and temperature controls.
The document is bilingual, with sections in both English and Danish, and includes safety warnings and error codes for maintenance and repair scenarios.
| Voltage Supply | 230 V AC; 50 Hz |
|---|---|
| Maximum Power Consumption | 2200 W |
| Operating Temperature Range | 4~38 °C |
| Relative Humidity Range | 25~85 % RH |
| Maximum Operating Altitude | 2000 m |
| Protection Rating | IPX4 |
| Minimum Water Pressure | 0,15 MPa (1,5 bar) |
| Maximum Water Pressure | 0,4 MPa (4 bar) |
| Boiler Capacity | 4 l or 8 l |
| Heating Time (10°C to 100°C) | 15 min (single), 21 min (combi) |
| Maximum Chlorine Level | 100 mg/l |
| Minimum Mixed Water Temperature | 35.8°C (combi only) |
| Maximum Mixed Water Temperature | 63.7°C (combi only) |
The boiler is not filled with water and is on (dry-run condition). This is a locked error that can only be reset by unplugging the power cord.
A valve is closed, a hose is bent, or there is no water pressure. Check that all valves are open, hoses are not bent, and water pressure is at least 0.15 MPa. Contact your water supplier if the issue persists.
The boiler is off, the plug is unplugged, or the grounding contact is open. Press the power button for at least 0.5 seconds, plug the boiler into a grounded outlet, and ensure the grounding contact is closed. Also check that the temperature selector on the mixing valve is set to a higher value.
This is normal and requires no action.