A.O. Smith 100263113 residential gas water heater guide covering safety, installation, operation, troubleshooting, and maintenance.
This document is the installation instructions and use & care guide for the A.O. Smith 100263113 residential gas water heater. It says to keep the manual in the pocket on the heater and to read it and the labels before installing, operating, or servicing the heater.
The guide covers important safety information, getting started, installation, operation, troubleshooting, maintenance, notes, and repair parts. It includes a completed installation diagram and warnings about fire, explosion, scalding, gas supply, and L.P. gas pressure.
| Lead content | Low lead content |
|---|---|
| Maximum L.P. gas supply pressure | 13” water column |
| Maximum gas supply pressure | As stated on the water heater’s data plate |
Do not try to light any appliance or touch any electrical switch. Call your gas supplier from a neighbor’s phone; if you cannot reach the supplier, call the fire department.
Keep this manual in the pocket on the heater for future reference when maintenance, adjustment, or service is required.
Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
Drain and flush the tank and remove and inspect the anode rod after the first six months of operation and at least annually thereafter.