A.O. Smith AO-WH-SOFT-PRO-300/AO-WH-SOFT-450T/AO-WH-SOFT-PRO-500 Water Softener User Manual

AO-WH-SOFT-PRO-300/AO-WH-SOFT-450T/AO-WH-SOFT-PRO-500 is a water softener developed by American A.O.Smith company. It features a built-in dirt and sediment filter and fine mesh resin that reduces scale buildup on internal pipes and plumbing.


A.O. Smith AO-WH-SOFT-PRO-300/AO-WH-SOFT-450T/AO-WH-SOFT-PRO-500 Water Softener User Manual - cover page
Brand
A.O.SMITH
Document type
User Manual
Language
English
Pages
24
File format
PDF
File size
1.1 MB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
BF99DEC102AF7DD52F9AD1C6557C213D

About this manual

This user manual provides step-by-step guidance for installing and maintaining A.O. Smith water softeners, including AO-WH-SOFT-PRO-300, AO-WH-SOFT-450T, and AO-WH-SOFT-PRO-500 models. It covers water testing, system configuration, valve setup, and safety precautions. The manual also includes troubleshooting tips and maintenance schedules to ensure optimal performance and longevity of the unit.

The document emphasizes the importance of professional installation, proper water testing for iron and hardness, and correct plumbing connections. It includes detailed instructions for setting up the softener, adjusting settings based on water quality, and handling common issues such as freezing or salt depletion.

What's inside

  • Box Contents
  • Before You Begin
  • Ferrous Iron and Compensated Hardness
  • Getting Maximum Efficiency from the Appliance
  • Precautions
  • Getting to Know Your New Softener
  • Valve Overview
  • System Configuration
  • Installation
  • Troubleshooting

Frequently asked questions

What are the model numbers for the water softener?

AO-WH-SOFT-PRO-300, AO-WH-SOFT-450T, AO-WH-SOFT-PRO-500.

What is the minimum water pressure for municipal water?

Water pressure must be greater than 20 psi (1.4 bar).

What is the recommended minimum inlet pipe size for municipal water?

The recommended minimum inlet pipe size is 1/2" (1.27 cm) I.D.

What should you do if ferrous iron is present in the water?

Increase your water hardness setting by 5 grains per gallon for every 1 ppm of ferrous iron.