A. O. Smith EWS-3 3 Litre Water Heater User Manual

This document is the installation manual of A.O.Smith EWS 3L water heater


A. O. Smith EWS-3 3 Litre Water Heater User Manual - cover page
Brand
A.O.SMITH
Category
Water heater
Document type
User Manual
Language
English
Pages
4
File format
PDF
File size
2.5 MB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
22F6FEF2F3A432F766FFB2152048325A

About this manual

This user manual covers the A. O. Smith EWS-3 wall-mounted water heater, manufactured by A. O. Smith India Water Products Private Limited. It describes installation requirements, mounting, plumbing and electrical connection, filling and draining, operation modes, troubleshooting and a circuit diagram.

The EWS-3 has a 3 litre volume, 3000/4500 W power, 230 V/50 Hz supply and a 25–60 °C temperature range. The manual states the multi-function safety valve is factory set at 0.8 MPa (8 Bar), and installation must be indoors with the water connections at the bottom.

What's inside

  • Safety Precautions
  • Mounting the Water Heater
  • Important Specifications
  • Filling the Water Heater Tank
  • Connecting to Electrical Supply
  • Operation
  • Modes
  • Draining the Water Heater Tank
  • Troubleshooting
  • Circuit Diagram

Specifications

ModelEWS-3
Volume3 L
Power3000/4500 W
Voltage/Frequency230 V/50 Hz
Temperature range25–60 °C
Rated water pressure80 N/cm²
Water head80 metres
Inlet/Outlet connections1/2 inch BSP
Net Weight4.2 kg
DimensionsA 384 mm, B 245 mm, C 66 mm, D 62 mm, E 205 mm

Frequently asked questions

What tools are needed before installing the water heater?

The listed tools are an adjustable wrench, Teflon tape, impact drill, hammer, bubble level indicator and measuring tape, plus the user manual.

Where should the water heater be installed?

It must be installed indoors, vertically with the water connections at the bottom, and not where there is direct sunlight or rain.

What is the factory setting of the multi-function safety valve?

The multi-function safety valve is factory fitted and set at 0.8 MPa (8 Bar) rated pressure.

Download PDF (2.5 MB)

More A.O.SMITH Manuals