TECO L510 Series AC Motor Drive User Manual


TECO L510 Series AC Motor Drive User Manual - cover page
Brand
TECO
Category
inverter
Document type
User Manual
Language
Chinese
Pages
95
File format
PDF
Published
04 November, 2011
Updated
29 September, 2023
Model
L510
MD5 checksum
50B4A388E2797E2F50FCDCEEC6DC5BA1

About this manual

The L510 is a microcomputer-controlled, IGBT-driven AC motor drive (inverter) from TECO. The series includes 100V-class models from 0.2 to 0.75 kW and 200V-class models from 0.2 to 2.2 kW in single-phase and three-phase versions. This Traditional Chinese user manual explains how to install, wire, configure and maintain the drive.

The manual opens with safety notices for the periods before power-on, during power-on, before and during operation, and during inspection and maintenance. It then describes the model code, installation environment and required mounting space, wiring rules and standard wiring, terminals and product specifications. Further chapters cover keypad and LED display operation, the parameter list and parameter functions, fault display and troubleshooting steps, daily and periodic inspection, peripheral components such as reactors, magnetic contactors and fuses, and an appendix parameter setting table. This manual is written in Chinese.

What's inside

  • Preface and safety notices
  • Safety precautions before and during power-on
  • Model designation and model list
  • Installation environment and installation space
  • Wiring rules and standard wiring
  • Terminal descriptions (main circuit and control circuit)
  • Keypad operation and parameter list
  • Fault display and troubleshooting
  • Daily and periodic inspection and maintenance
  • Peripheral components (reactor, contactor, fuse)

Specifications

Applicable motor capacity, 100V class0.2~0.75 kW (0.53~1.6 kVA)
Applicable motor capacity, 200V class0.2~2.2 kW (0.53~4.0 kVA)
Input voltage, single-phase models100~120V or 200~240V, +10%/-15%
Input voltage, three-phase models200~240V, +10%/-15%, 50/60Hz
Protection ratingIP20
Operating temperature-10~40°C (-10~50°C for models with built-in fan)
Storage temperature-20~60°C
Humidity95%RH or less, no condensation
Vibration resistance1G at 20Hz or below; 0.6G at 20~50Hz
Short-circuit capacity5000A/120V or 5000A/240V
EMC standardIEC 61800-3, restricted distribution level

Frequently asked questions

How long must I wait after switching off the power before servicing the L510?

Wait 5 minutes after the power is removed; the DC capacitors need this time to discharge before disassembly or inspection.

What is the protection rating of the L510 drive?

The drive has an IP20 protection rating.

What input voltage do the single-phase L510 models use?

Single-phase models are made for 100~120V or 200~240V input with +10%/-15% tolerance.

What is the permitted operating temperature?

The operating temperature is -10~40°C, or -10~50°C for models with a built-in fan.