The L510 is a microcomputer-controlled, IGBT-driven AC motor drive (inverter) from TECO. The series includes 100V-class models from 0.2 to 0.75 kW and 200V-class models from 0.2 to 2.2 kW in single-phase and three-phase versions. This Traditional Chinese user manual explains how to install, wire, configure and maintain the drive.
The manual opens with safety notices for the periods before power-on, during power-on, before and during operation, and during inspection and maintenance. It then describes the model code, installation environment and required mounting space, wiring rules and standard wiring, terminals and product specifications. Further chapters cover keypad and LED display operation, the parameter list and parameter functions, fault display and troubleshooting steps, daily and periodic inspection, peripheral components such as reactors, magnetic contactors and fuses, and an appendix parameter setting table. This manual is written in Chinese.
| Applicable motor capacity, 100V class | 0.2~0.75 kW (0.53~1.6 kVA) |
|---|---|
| Applicable motor capacity, 200V class | 0.2~2.2 kW (0.53~4.0 kVA) |
| Input voltage, single-phase models | 100~120V or 200~240V, +10%/-15% |
| Input voltage, three-phase models | 200~240V, +10%/-15%, 50/60Hz |
| Protection rating | IP20 |
| Operating temperature | -10~40°C (-10~50°C for models with built-in fan) |
| Storage temperature | -20~60°C |
| Humidity | 95%RH or less, no condensation |
| Vibration resistance | 1G at 20Hz or below; 0.6G at 20~50Hz |
| Short-circuit capacity | 5000A/120V or 5000A/240V |
| EMC standard | IEC 61800-3, restricted distribution level |
Wait 5 minutes after the power is removed; the DC capacitors need this time to discharge before disassembly or inspection.
The drive has an IP20 protection rating.
Single-phase models are made for 100~120V or 200~240V input with +10%/-15% tolerance.
The operating temperature is -10~40°C, or -10~50°C for models with a built-in fan.