TOA DA-250F/DA-250FH Multichannel Power Amplifier User Manual

This document is the user manual for TOA DA-250F and DA-250FH multi-channel power amplifiers, which introduces the safety precautions, overview, features, usage considerations, installation considerations, button settings and speaker connection methods, removable terminal plug connection methods, input sensitivity setting methods, protection action list, filter cleaning methods, etc.


Brand
TOA
Category
Industrial Supply
Document type
User Manual
Language
Chinese
Pages
19
File format
PDF
File size
566 KB
Updated
28 September, 2023
MD5 checksum
B7EC7D1B396F40C3FD060647FBC74663

About this manual

This manual provides safety precautions, installation guidelines, and detailed operation instructions for the TOA DA-250F and DA-250FH multichannel power amplifiers. It includes descriptions of front and rear panel functions, button settings, speaker connections, and filter cleaning procedures.

The document also lists technical specifications such as output power, frequency response, distortion, input sensitivity, and environmental limits, along with a parts list and dimensions for proper rack mounting. This manual is written in Chinese.

What's inside

  • Safety Precautions
  • Overview
  • Features
  • Installation Notes
  • Front and Rear Panel Description
  • Button Settings and Speaker Connection
  • Input Sensitivity Settings
  • Protection Action List
  • Filter Cleaning Method
  • Specifications

Specifications

Output Power (8Ω)170W x 4
Output Power (4Ω)250W x 4
BTL Output Power500W (8Ω) x 2
Frequency Response20Hz~20kHz (8Ω), 50Hz~20kHz (4Ω)
Total Harmonic Distortion0.1%–0.3%
Input Sensitivity+4dB (1.23V) / -10dB (0.24V)
Input Impedance10kΩ (balanced)
Signal‑to‑Noise Ratio105 dB
Power Supply VoltageAC 220‑240V, 50/60 Hz
Power Consumption200 W per 4‑channel set
Operating Temperature-10 °C to +40 °C
Operating Humidity≤90 % RH (no condensation)
Dimensions (W×H×D)482 mm × 44 mm × 400 mm
Weight6.8 kg

Frequently asked questions

What is the recommended operating temperature range?

The amplifier should be used in temperatures from –10 °C to +40 °C.

How many watts per channel does the DA-250F provide at 4 Ω?

It provides 250 W per channel at 4 Ω.

How should the filter be cleaned?

Remove the heat‑sink panel and clean the filter inside.

What safety step must be taken before connecting speakers?

Turn off the power before connecting the speaker cables.

Download PDF (566 KB)

More TOA Manuals


View all TOA manuals →