Bosch ICP‑CC488 Series Control Master User Manual


Brand
Bosch
Category
Other
Document type
User Manual
Language
Chinese
Pages
4
File format
PDF
Published
21 September, 2011
Updated
29 September, 2023
MD5 checksum
E0429BB8972CF3BDDD8969EB45CFBD1F

About this manual

The ICP‑CC488 control master provides up to eight programmable wired or wireless zones, two partitions, and a range of alarm functions such as daytime, coercion, and keyboard anti‑tamper alarms. Remote programming can be performed via a PC running MS‑DOS with the CC816 Alarm Link (A‑Link) software, allowing configuration from hundreds of kilometres away.

Technical data include current consumption (115 mA alarm, 105 mA with keyboard, 65 mA standby), power requirements (240 VAC primary, 18 VAC secondary, 12 VDC backup 6.5 Ah), environmental limits (10 %–95 % RH, 0 °C–+45 °C), dimensions (306 mm × 262 mm × 84 mm) and weight (2.5 kg). The manual also lists compatible RF receivers, accessories, and ordering information for various regional variants. This manual is written in Chinese.

What's inside

  • Basic Functions
  • Remote Programming
  • Arming Modes
  • Alarm Types
  • Dynamic Battery Test
  • Event Memory Recall
  • Electrical Specifications
  • Hardware Accessories
  • Ordering Information

Specifications

Alarm state current consumption115 mA
Current consumption with keyboard105 mA
Standby current consumption65 mA
Primary power input240 VAC
Secondary power input18 VAC, 1.3 A
Backup power12 VDC, 6.5 Ah sealed lead‑acid battery
Operating temperature range0 °C to +45 °C
Relative humidity range10 % to 95 % (no condensation)
Dimensions (W × H × D)306 mm × 262 mm × 84 mm
Weight2.5 kg

Frequently asked questions

How many programmable user codes does the ICP‑CC488 support?

It supports up to eight user codes and eight wireless remote codes.

How often does the dynamic battery test run?

The battery test runs automatically every four hours and also each time the system is armed.

Can the control master be programmed remotely?

Yes, remote programming is possible using a PC with MS‑DOS and the CC816 Alarm Link (A‑Link) software over a modem connection.